Lincoln Electric IM837-A manual Operation, General Description

Page 20

B-1

OPERATION

B-1

 

 

 

SAFETY PRECAUTIONS

WARNING

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

Always operate the welder with the hinged door closed and the side panels in place.

Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.

GENERAL DESCRIPTION

The RANGER 305D (CE) is a diesel engine powered DC multi-process welding power source and AC power generator. The engine drives a generator that supplies three phase power for the DC welding circuit and three phase and single phase power for the AC auxiliary outlets. The DC welding control system uses state of the art Chopper Technology (CT TM) for supe- rior welding performance.

FOR AUXILIARY POWER:

Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.

ENGINE OPERATION

Before Starting the Engine:

Be sure the machine is on a level surface.

Open top & side engine doors and remove the engine oil dipstick and wipe it with a clean cloth. Reinsert the dipstick and check the level on the dip- stick.

Add oil (if necessary) to bring the level up to the full mark. Do not overfill. Close engine door.

Check radiator for proper coolant level. (Fill if nec- essary).

See Engine Owner’s Manual for specific oil and coolant recommendations.

ADD FUEL

WARNING

• Stop engine while fueling.

• Do not smoke when fueling.

Keep sparks and flame away from tank.

Do not leave unattended while fueling.

DIESEL FUEL • Wipe up spilled fuel and allow can cause fire. fumes to clear before starting

engine.

Do not overfill tank, fuel expansion may cause over- flow.

DIESEL FUEL ONLY

------------------------------------------------------------------------

Remove the fuel tank cap.

Fill the tank approximately 4 inches (100mm) from the top of the filler neck to allow for fuel expansion (observe the fuel gauge while filling). DO NOT FILL THE TANK TO THE POINT OF OVERFLOW.

Replace the fuel cap and tighten securely.

See Engine Owner’s Manual for specific fuel recom- mendations.

BREAK-IN PERIOD

Any engine will use a small amount of oil during its “break-in” period. For the diesel engine on the RANGER 305D (CE), break-in is about 50 running hours.

Check the oil every four hours during break-in. Change the oil after the first 50 hours of operation, every 100 hours thereafter. Change the oil filter at the second oil change.

CAUTION

During break-in, subject the RANGER 305D (CE) to moderate loads. Avoid long periods running at idle. Before stopping the engine, remove all loads and allow the engine to cool several minutes.

------------------------------------------------------------------------

RANGER 305D (CE)

Image 20
Contents Ranger 305 D CE Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcSafety Spain Ranger 305D CEVii Viii Thank You Table of Contents Section D Section ESection F P494Installation Technical Specifications Ranger 305D CESafety Precautions Location and VentilationPRE-OPERATION Engine Service TowingVehicle Mounting OILElectrical Connections Auxiliary Power Standby Power ConnectionsWelding Terminals Welding Output CablesConnection of Lincoln Electric Wire Feeders Connection of LN-15 to the Ranger 305DAcross The-Arc Model Control Cable ModelConnection of LN-742 and Cobramatic to Ranger 305D CE Connection of Prince XL Spool GUN toOperation General DescriptionWeld Mode Selector Switch Digital Output MetersGlow Plug Push Button Wire Feeder Voltmeter SwitchGround Stud Starting the Engine Stopping the EngineTypical Ranger 305D CE Fuel Consumption Table B.1Welder Operation Typical Current Ranges 1 for Tungsten ELECTRODES2Duty Cycle TIG WeldingWire WELDING-CV Simultaneous Welding and Auxiliary Power LoadsARC Gouging 8000 Amps 6500 100 5000 150 3500 200 2000 250Accessories Field Installed Options AccessoriesKubota D722 Diesel Engine MaintenanceEngine Maintenance Components Kubota D722 Diesel Engine OIL Filter Change AIR CleanerEngine OIL Refill Capacities Without oil filter replacement Service Instructions & Installation Tips 3MAINTENANCED-3Cooling System Tightening the FAN BeltBleeding the Fuel System For Codes 11122Engine Adjustment Battery MaintenanceServicing Optional Spark ArrestorWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service FacilityYour local Lincoln Welding without a control cable Functioning properly / linkage Troubleshooting Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Engine Welders /LN-742 Connection Diagram Diagrams Diagrams Enhanced Diagram Ranger 305D CE Kubota Wiring Diagram UK for Code Diagrams Ranger 305D CE Kubota Wiring Diagram -EUROPE for Code Dimension Print Center of GravityRanger 305D CE Ranger 305D CE Ranger 305D CE Precaucion Guards off