| OPERATION |
| ||
|
|
|
|
|
●No external shielding gas is required when used with Lincoln Innershield .035” (0.9 mm)
●Accommodates both 4” (100 mm) diameter and 8” (200 mm) diameter spools of wire.
●Accepts optional Spot/Stitch Timer Kit.
WELDING CAPABILITY
The
LIMITATIONS
Arc Gouging cannot be performed with the
CONTROLS AND SETTINGS
5. Gun Trigger - Activates welding output, wire feed, |
and gas solenoid operation. Releasing the trigger |
deactivates welding and simultaneously activates |
the “burnback” function so that the welding wire |
does not stick in the weld puddle. |
6. Optional |
(see ACCESSORIES section) - If present, replaces |
Blank Panel Assembly located on the center panel |
inside the case door: |
Mode Switch - Selects between Spot, Stitch, or |
Seam (normal welding) mode. Spot mode welds |
for an adjustable length of time (set by Time |
Control; see below) and then stops, whenever the |
gun trigger is depressed and held. Stitch mode |
cycles between welding and not welding for an |
adjustable length of time (also set by Time Control) |
while the gun trigger is depressed. In Seam mode |
the machine will weld continuously while the gun |
trigger is depressed. Releasing the gun trigger in |
any of the three modes will interrupt welding imme- |
diately. |
Refer to Figure B.1a.
1.Control Power ON/OFF Switch
— When the power is on the fan motor will run and air will be exhausted out the louvers in the front of the machine. The weld- ing output and wire feeder remain off until the gun trigger is pressed.
2.Wire Speed Control — Controls the wire feed speed from 50 – 300 in /min (1.3 – 7.6 m/min). The control can be preset on the dial to the setting specified on the SP- 135T Application Chart located on the inside of the wire feed section door.
3.Voltage Control — A
OFF
ON
WIRE SPEED
ARC VOLTS
Time Control - In Spot mode, controls spot mode |
ON time between approximately .25 and 4.0 sec- |
onds. In Stitch mode, controls stitch mode ON time |
and OFF time simultaneously between .25 and 4.0 |
seconds each. This control is deactivated while in |
Seam mode. |
4.Circuit Breaker – Protects machine from damage if maximum output is exceeded. Button will extend out when tripped (Manual reset) Refer to Figure B.1b.