Lincoln Electric LF-72/74 service manual Test Procedure, Figure F.3 Leads 552, 552B

Page 94

Section TOC

Master TOC

F-10

TROUBLESHOOTING AND REPAIR

F-10

 

 

GAS SOLENOID TEST

(continued)

Return to

Return to

FIGURE F.2 - GAS SOLENOID

FIGURE F.3 – LEADS 552, 552B & 553

Return to Section TOC

Return to Master TOC

GAS SOLENOID

Located on case back

Coil measures

21 ohms GAS SOLENOID

Off = 0 VDC

OCV = 59 VDC

On = 7.7 VDC

553

552

552B

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove the input power from the LF72/LF74 unit.

2.Using the 5/16 nut driver, remove the 5 screws holding the cover.

3.Locate the gas solenoid (FIG F.2) on the back of the feeder.

4.Apply the correct (42VAC) input voltage to the unit.

5.While pressing the gas purge button or activating the gun trigger, check for approximately 8VDC at the solenoid leads (FIG F.3). If the 8VDC is present the solenoid should activate. If the 8VDC is present but the solenoid does not activate the solenoid may be faulty.

6.If the 8VDC is missing or low, check the leads and connections between the solenoid and the control board. See the wiring diagram. If the leads and connections are ok, the control board may be faulty.

7.Normal solenoid coil resistance is 21 ohms.

8.The solenoid can be further checked by disconnecting the leads and applying 12VDC directly to the terminals. If the solenoid does not activate the solenoid is faulty.

9.Reconnect the leads and replace the cover.

LF-72/74

Image 94
Contents LF-72/74 Safety Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Installation Section Table of ContentsSection A-1 Installation Amp Rating Duty CycleLocation Safety PrecautionMounting Boom Mount Bench MountSwivel Mount SuspendedWeld Cable Sizes Coaxial Weld Cables Weld Cable ConnectionAnalog Control Cable INSTALLATIONA-7Control Cable Connections Analog Miller Control Cable Adapter K2335-1 Miller Power Source Lincoln Wire FeederPin Function Remote Sense Lead Specifications Wire Drive SystemsWelding GUN/WIRE Feeder Trigger Connector High Frequency ProtectionWelding GUNS, Torches and ACCES- Sories Magnum GUN and Cable AssembliesWire Drive Configuration Procedure for Changing Drive and Idle Roll SetsRolls.FIGURE A.4 Gun Receiver For use With Bushing Pressure ARM AdjustmentSet the pressure arm as follows See Figure A.6 Wire Reel Loading Weld Wire Routing Figure A.9Shielding GAS Connection Conduit Kits Installing ElectrodeTo install Lincoln conduit See Figure A.10b For Codes 11209, 11210, 11211 and aboveAluminum Wire Preparations Figure A.12bINSTALLATIONA-18 Base Model Bench Model Standard Duty Bench Model Heavy DutyTypical System Configurations CableLF-72/74 Operation Section Section B-1Operation GAS Input Work ConnectionProduct Description Common Welding AbbreviationsRecommended Processes Front Panel Controls and Connections Figure B.1 Case Front Controls DescriptionStep Trigger Interlock Switch Burnback and Postflow Timer KITCold FEED/GAS Purge Switch Remote Voltage Control KITGUN Receiver Bushing K1500-2 Wire Feed Speed KnobTrigger Connector 5-PIN Amphenol Trigger InterlockAccessories Section Section C-1Accessories Optional KitsLF-72s Accessories Key LF-72/74 Maintenance Section Section D-1Calibration Specification MaintenanceMaintenance Routine MaintenanceFigure D.1 Figure D.3 Major Component Location Section AA-1 Section AAAA-2 WFS Range Wire SizesModel AA-3 Figure AA.1AA-4 AA-5 AA-6 Coaxial Weld CableAA-7 INSTALLATIONAA-7K1797-xx AA-8 Drive Roll Kits Steel or Cored Wires AA-9AA-10 Figure AA.3Lation or changing drive rolls and/or AA-11Changing the Gun Receiver Bushing GuidesAssembly of Drive Rolls and Wire Guides AA-12AA-13 Set the pressure arm as follows See Figure AA.8AA-14 AA-15 Loading 16 to 44 lb .3 20kg Spools See figure AA.8AA-16 Figure AA.11AA-17 Figure AA.12aAA-18 Figure AA.12bAA-19 AA-20INSTALLATIONAA-20 Common Equipment SET-UPSFigure AA.15 High Volume Production AA-21Figure AA.16 Portable Welding AA-22Section BB-1 Section BBBB-2 Fcaw Innershield or OutershieldRequired Equipment BB-3BB-4 Figure BB.1 Case Front Controls DescriptionK2426-1 and K2426-2 models BB-5K2426-3 model Switch BB-6Section CC-1 CC-2 CC-3 CC-4 CC-5 CC-6 Section DD-1 Section DDWhen inching with gun trigger, electrode To verify the wire feed speedNal wiring WFS knob setting Could remain energized Several secondsMAINTENANCEDD-3 DD-3Figure DD.3 Major Component Location DD-4Theory of Operation Section Section E-1Theory of Operation Return to SectionControl Board LF-72/74 Troubleshooting & Repair Section Section F-1Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures Function Problems Function Problems Troubleshooting & Repair Drive Motor and Tach Feedback Test Test DescriptionTest Procedure Troubleshooting and Repair GAS Solenoid TestTest Procedure Figure F.3 Leads 552, 552BDiode Bridge Test 552B + 552A Wire Speed Potentiometer Test Wire Speed Potentiometer Test 14F-14PC Board Removal and Replacement Control PC Board Removal and Replacement Procedure Removal Procedure Replacement ProcedureTroubleshooting and Repair Wire Drive Motor and Gear BOX Removal and Replacement ProcedureProcedure Replacement Procedures SET UP Operation VerificationLF-72/74 Electrical Diagrams Section Section G-1Electrical Diagrams LF-72/74Timer KIT Board Normal Speed Micro Internal panel Motor Connecter Summary High Torque Setting engages Schematic Common Analog Control PC Board G4559 Sheet Electrical Diagrams Electrical Diagrams PC Board Assembly Common Analog Control G4560-2E0