Lincoln Electric K1780-1 Ging the Wire Drive Ratio, Electric Shock can kill, Power Wave 455/R

Page 12

A-5

INSTALLATION

A-5

CHAN

GING THE WIRE DRIVE RATIO

5.

Remove the small gear from the output shaft.

 

WARNING

 

 

Lightly cover the output shaft with engine oil or

 

 

 

with flat washer, lock washer, and Phillips head

 

ELECTRIC SHOCK can kill.

 

 

equivalent. Install gear onto output shaft and secure

 

 

 

screw which were previously removed.

 

• Turn off power to the power source

6. Tighten the screw on lower right face of feed plate.

 

at the disconnect switch.

7. Re-attach feed plate to wire feeder if removed in

------------------------------------------------------------------------

 

Step 2.

 

Changing the ratio requires a gear change and a PC

8. Feed plate will be rotated out-of-position due to the

board switch change. The Power Feed Wire Feeders

are shipped with both high speed and a low speed

 

gear change. Adjust the angle of the feed plate per

gears.

As shipped from the factory, the low speed

 

Item 2.

 

(high torque) gear is installed on the feeder. For iden-

Set the High/Low switch code on Wire Drive PC board

tification purposes, the low speed (high torque) gear

has 20 teeth and is 1.1 inches in diameter. The high

which is located on the

Power Wave 455/R and

speed gear has 30 teeth and is 1.6 inches in diameter.

Power Wave 655/R. Consult the Instruction Manual

1. Pull open the Pressure Door.

for proper power source settings.

2. Remove the Phillips head screw retaining the pinion gear to be changed and remove the gear. If the gear is not easily accessible or difficult to remove, remove or adjust feed plate from the gearbox. To remove feed plate:

• Loosen the clamping collar screw using a 3/16" Allen wrench. The clamping collar screw is accessed from the bottom of the feed plate. It is the screw which is perpendicular to the feeding direction.

• Loosen the retaining screw, which is also accessed from bottom of feeder, using a 3/16" Allen wrench. Continue to loosen the screw until the feed plate can be easily pulled off of the wire feeder.

3. Loosen, but do not remove, the screw on the lower right face of the feed plate with a 3/16" Allen wrench.

4. Remove the screw on the left face of the feed plate. If changing from high speed (larger gear) to low speed (smaller gear), line the lower hole on the left face of the feed plate with the threads on the clamping collar. Line the upper hole with the threads to install larger gear for high speed feeder. If feed plate does not rotate to allow holes to line up, further loosen the screw on right face of feed plate.

POWER FEED 10 / R

Image 12
Contents IM689-A Safety For EngineElectric Magnetic Fields Califo Rnia Proposition 65 WarningsARC Rays can burn Electric Shock can Kill Fumes and GasesFor Electrically IiiPrécautions DE Sûreté LES Machines À Souder ÀTransformateur ET À RedresseurPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationInstallation Section a DiagramsSection C Section EInstallation Technical Specifications Power Feed 10 Robotic-K1780-1SAF ETY Precautions Electrode RoutingElectrode and Work Cable CON NectionsControl Cable Shielding GAS ConnectionNegative Electrode Polarity Control Cable ConnectionsSpeed Selecting the Proper Gear RatioAvailable Cable Assemblies Ging the Wire Drive Ratio Turn off power to the power sourceAt the disconnect switch Power Wave 455/RWire Feed Drive Roll Kits Procedure to Install Drive RollsWire Guides General GUN Connection GuidelinesRemote Sense Lead Specifications Installation of Field InstalledGUN Receiver Bushings Conduit Adapters Non-Lincoln GunsFeed Ing Electrode and Brake Adjustment Drive Roll Pressure SettingOperation General DescriptionRecommended Processes Process LimitationsAccessories Operational Features and ControlsIonal Equipment Platform CommonalitiesMaintenance Avoiding Wire Feeding ProblemsRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideSymptoms ProblemsPossible Cause RecommendedPossible Cause Recommended Symptoms Course of Action Field Service FacilityYour local Lincoln Authorized Troubleshooting Diagrams Power Feed 10 / R Dimension Print Power Feed 10 / R Power Feed 10 / R Ground Aspiración para gases