Lincoln Electric K1780-1 manual Accessories, Ional Equipment, Platform Commonalities

Page 17

C-1

 

 

 

ACCESSORIES

 

 

C-1

OPT

IONAL EQUIPMENT

 

• Power Feed 10 series Feedhead.

 

 

 

 

 

 

PLATFORM COMMONALITIES

 

• KP1505 Drive Roll and Wire Guide Kits

 

• CGA gas connections.

 

 

• Quick connect water connections.

 

• KP1507 Drive Roll and Wire Guide Kits

 

• Works with all PowerWave ArcLink systems. “It is

The KP1507 series of drive roll kits contain a number

not compatible with the PowerWave 350, 450 or 500

of components, in addition to the drive rolls, to opti-

or Linc-net PowerWave 455ʼs”

 

components are specifically designed to protect the

OPERATIONAL FEATURES AND CONTROLS

mize the wire feeder for aluminum feeding. These

• All procedure settings for the Power Feed 10 Robotic

aluminum wire from abrasion and deformation, there-

by avoiding many common aluminum feeding prob-

wire feeder is through software control. A DIP switch

lems.

 

 

is used to indicate hardware settings.

 

• K1546 Conduit

 

 

 

 

 

 

 

 

TABLE C.1 – DRIVE ROLL AND GUIDE TUBE KITS

 

 

 

 

 

 

 

 

 

Wire Size

 

KP No. Series

 

 

 

 

Solid Steel Electrode

 

 

 

 

 

0.023” - 0.025”

(0.6 mm)

 

KP1505 - 030S

 

 

 

 

0.030”

 

(0.8 mm)

 

KP1505 - 030S

 

 

 

 

0.035”

 

(0.9 mm)

 

KP1505 - 035S

 

 

 

 

0.040”

 

(1.0 mm)

 

KP1505 - 045S

 

 

 

 

0.045”

 

(1.2 mm)

 

KP1505 - 045S

 

 

 

 

0.052”

 

(1.4 mm)

 

KP1505 - 052S

 

 

 

 

1/16”

 

(1.6 mm)

 

KP1505 - 1/16S

 

 

 

 

5/64”

 

(2.0 mm)

 

KP1505-5/64

 

 

 

 

3/32”

 

(2.4 mm)

 

KP1505-3/32

 

 

 

 

0.030

Cored Electrode

 

KP1505 - 035C

 

 

 

 

(0.8 mm)

 

 

 

 

 

0.035”

 

(0.9 mm)

 

KP1505 - 035C

 

 

 

 

0.040”

 

(1.0 mm)

 

KP1505 - 045C

 

 

 

 

0.045”

 

(1.2 mm)

 

KP1505 - 045C

 

 

 

 

0.052”

 

(1.4 mm)

 

KP1505 - 052C

 

 

 

 

1/16”

 

(1.6 mm)

 

KP1505 - 1/16C

 

 

 

 

0.068”

 

(1.7 mm)

 

KP1505 - 068

 

 

 

 

5/64”

 

(2.0 mm)

 

KP1505 - 5/64

 

 

 

 

3/32”

 

(2.4 mm)

 

KP1505 - 3/32

 

 

 

 

7/64” Lincore Hard Facing (2.8mm)

 

KP1505 - 7/64H

 

 

 

 

7/64”

 

(2.8mm)

 

KP1505 - 7/64

 

 

 

 

.120”

 

(3.0mm)

 

KP1505 - 120

 

 

 

 

Aluminum Electrode

 

KP1507 - 035A

 

 

 

 

0.035”

 

(0.9 mm)

 

 

 

 

 

0.040”

 

(1.0 mm)

 

KP1507 - 040A

 

 

 

 

3/64”

 

(1.2 mm)

 

KP1507 - 3/64A

 

 

 

 

1/16”

 

(1.6 mm)

 

KP1507 - 1/16A

 

 

 

 

3/32”

 

(2.2 mm)

 

KP1507 - 3/32A

 

 

 

 

 

 

POWER FEED 10 / R

 

 

 

 

 

 

 

 

 

 

Image 17
Contents IM689-A For Engine SafetyElectric Magnetic Fields Califo Rnia Proposition 65 WarningsFumes and Gases ARC Rays can burn Electric Shock can KillIii For ElectricallyLES Machines À Souder À Précautions DE SûretéTransformateur ET À RedresseurOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyDiagrams Installation Section aSection C Section ETechnical Specifications Power Feed 10 Robotic-K1780-1 InstallationElectrode Routing SAF ETY PrecautionsElectrode and Work Cable CON NectionsShielding GAS Connection Control CableNegative Electrode Polarity Control Cable ConnectionsAvailable Cable Assemblies SpeedSelecting the Proper Gear Ratio Turn off power to the power source Ging the Wire Drive RatioAt the disconnect switch Power Wave 455/RProcedure to Install Drive Rolls Wire Feed Drive Roll KitsWire Guides General GUN Connection Guidelines Installation of Field Installed Remote Sense Lead Specifications GUN Receiver Bushings Conduit Adapters Non-Lincoln GunsDrive Roll Pressure Setting Feed Ing Electrode and Brake AdjustmentGeneral Description OperationRecommended Processes Process LimitationsOperational Features and Controls AccessoriesIonal Equipment Platform CommonalitiesAvoiding Wire Feeding Problems MaintenanceRoutine Maintenance Periodic MaintenanceHOW to USE Troubleshooting Guide TroubleshootingProblems SymptomsPossible Cause RecommendedYour local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Diagrams Power Feed 10 / R Dimension Print Power Feed 10 / R Power Feed 10 / R Ground Aspiración para gases