Lincoln Electric IM481-B manual Electric Shock can kill

Page 3

ii

SAFETY

 

ii

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When

welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circum- stances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe- cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.

5.c. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating prod- ucts.

5.d. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.e. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.f. Also see item 1.b.

3

Image 3
Contents IM481-B Safety Depends on YouSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Output Control Dial Meanings of Graphic SymbolsPower ON-OFF Switch Output Control LOCAL-REMOTE SwitchVoltmeter Switch Circuit BreakerThermal Protection Light Degree of protection provided by the enclosure Rating PlateSignifying the Chassis Ground Connection Earth Ground ConnectionSignifying the Earth Ground Connection Chassis Ground ConnectionDesign Summary Operational Features & ControlsGeneral Machine Description Recommended Processes & EquipmentCase Features Auxiliary Power ConnectionsRemote Control Connections WATER COOLER CONNECTORMachine & Circuit Protection Thermal Protection Light ParallelingMETER OPTION Technical Specifications FALLING EQUIPMENT can cause InstallationSafety Precautions Input Power ConnectionsElectric Shock can kill Installation of Field Installed OptionsOutput Cable Connections Output CablesWire Feeder Control Cable Connections Undercarriages K817P, K841Connection of CV 500-I to LN-22 or LN-25 Duty Cycle Amps Volts Power Source OperationSafety Precautions ELECTRIC SHOCK can kill Operating InstructionsFront View of 14-PIN Connector Receptacle PIN LEAD NO FunctionTerminal Strip Connections VAC Auxiliary Power for Water Cooler Routine MaintenanceMachine and Circuit Protection HOW to USE Troubleshooting Guide TroubleshootingTrouble Cause What To Do TROUBLESHOOTING GUIDEFaulty Output Control potentiometer Trouble Cause What To Do Output Voltage Connecting the Remote Control to the MachineFault Protection Operation Power I/O Switch CheckPower Silicon Controlled Rectifier Test Remote Control CheckPower Rectifier Bridge Assembly Checking Procedure Power Diode TestRubber Boot To plug To T1 main transformer Gate leads plug to Control P.C. boardEnhanced Diagram Page Page Precaucion Warnung