Lincoln Electric IM481-B manual Faulty Output Control potentiometer

Page 24

Trouble

 

Cause

 

What To Do

 

 

 

 

 

Machine has low output and no con-

1.

Output Control “Local-Remote”

1.

Check position of switch.

trol.

 

switch (S2) in wrong position.

 

 

 

2.

Output Control switch faulty.

2.

Check switch and replace if

 

 

 

 

faulty.

 

3.

Open in feedback circuitry.

3.

Check wiring and control PC

 

 

 

 

Board wiring harness plugs.

 

4.

Faulty Control PC Board.

4.

Replace. See Procedure for

 

 

 

 

Replacing PC Boards.

 

5.

Output control potentiometer cir-

5.

Check and replace potentiometer

 

 

cuit open (Lead 75).

 

if faulty. Check wiring of Lead

 

 

 

 

#75.

 

 

 

 

 

Machine does not have maximum

1.

One input fuse blown.

1.

Check and replace if blown after

output.

 

 

 

checking for reason for blown

 

 

 

 

fuse.

 

2.

One phase of main transformer

2.

Check for open and repair.

 

 

open.

 

 

 

3.

Faulty Control PC Board.

3.

Replace. See Procedure for

 

 

 

 

Replacing PC Boards.

 

4.

Output control potentiometer

4.

Check and replace if faulty.

 

 

defective.

 

 

 

5.

Output control potentiometer

5.

Check and repair broken leads.

 

 

Leads 210, 211, or 75 open.

 

 

 

 

 

 

 

Machine will not shut off.

1.

Input contactor contacts frozen.

1.

Check and replace if necessary.

 

2.

Defective Power “I/O

2.

Replace.

 

 

switch, (S1).

 

 

 

 

 

 

 

Variable or sluggish welding arc.

1.

Poor work or electrode connec-

1.

Check and clean all connections.

 

 

tion.

 

 

 

2.

Welding leads too small.

2.

Check table in instruction manual.

 

3.

Welding current or voltage too

3.

Check procedures for recom-

 

 

low.

 

mended settings.

 

4.

Defective main SCR bridge.

4.

Check and replace if defective.

 

 

 

 

 

Output control not functioning on the

1.

Output Control “Local-Remote”

1.

Place switch in “Local”.

machine.

 

switch (S2) in wrong position.

 

 

 

2.

Faulty Output Control switch.

2.

Check and replace if found faulty.

 

3.

Faulty Output Control potentiometer.

3.

Check and replace if found faulty.

 

4.

Leads or connections open in

4.

Check lead continuity and con-

 

 

control circuit.

 

nections for an open and repair if

 

 

 

 

necessary.

 

5.

Faulty Control PC Board.

5.

Replace. See Procedure for

 

 

 

 

Replacing PC Boards.

 

 

 

 

 

24

Image 24
Contents Safety Depends on You IM481-BSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Table of Contents Meanings of Graphic Symbols Power ON-OFF SwitchOutput Control LOCAL-REMOTE Switch Output Control DialVoltmeter Switch Circuit BreakerThermal Protection Light Rating Plate Degree of protection provided by the enclosureEarth Ground Connection Signifying the Earth Ground ConnectionChassis Ground Connection Signifying the Chassis Ground ConnectionOperational Features & Controls General Machine DescriptionRecommended Processes & Equipment Design SummaryAuxiliary Power Connections Remote Control ConnectionsWATER COOLER CONNECTOR Case FeaturesMachine & Circuit Protection Thermal Protection Light ParallelingMETER OPTION Technical Specifications Installation Safety PrecautionsInput Power Connections FALLING EQUIPMENT can causeInstallation of Field Installed Options Output Cable ConnectionsOutput Cables Electric Shock can killWire Feeder Control Cable Connections Undercarriages K817P, K841Connection of CV 500-I to LN-22 or LN-25 Power Source Operation Safety Precautions ELECTRIC SHOCK can killOperating Instructions Duty Cycle Amps VoltsFront View of 14-PIN Connector Receptacle PIN LEAD NO FunctionTerminal Strip Connections VAC Auxiliary Power for Water Cooler Routine MaintenanceMachine and Circuit Protection Troubleshooting HOW to USE Troubleshooting GuideTROUBLESHOOTING GUIDE Trouble Cause What To DoFaulty Output Control potentiometer Trouble Cause What To Do Connecting the Remote Control to the Machine Fault Protection OperationPower I/O Switch Check Output VoltageRemote Control Check Power Rectifier Bridge Assembly Checking ProcedurePower Diode Test Power Silicon Controlled Rectifier TestRubber Boot Gate leads plug to Control P.C. board To plug To T1 main transformerEnhanced Diagram Page Page Precaucion Warnung