TROUBLESHOOTING GUIDE
Trouble |
| Cause |
| What To Do |
|
|
|
|
|
Input contactor (CR1 chatters). | 1. | Faulty input contactor (CR1). | 1. | Repair or replace. |
| 2. | Low line voltage. | 2. | Check input power. |
|
|
|
| |
Machine input contactor does not | 1. Supply line fuse blown. | 1. | Replace if blown - look for reason | |
operate. |
|
|
| first. |
| 2. | Contactor power circuit dead. | 2. | Check control transformer T2 |
|
|
|
| and associated leads. |
| 3. | Broken power lead. | 3. | Check input voltage at contactor. |
| 4. | Wrong input voltage. | 4. | Check voltage against instruc- |
|
|
|
| tions. |
| 5. | Open input contactor coil. | 5. | Replace coil. |
| 6. | POWER “I/O” switch (S1) not | 6. | Replace switch. |
|
| closing. |
|
|
|
|
|
|
|
Machine input contactor operates, | 1. | Circuit between #2 (C ) and #4 | 1. | Make sure trigger circuit is being |
but no output when trying to weld. |
| (D) is not being closed. |
| closed. |
| 2. | Electrode or work lead loose or | 2. | Repair connection. |
|
| broken. |
|
|
| 3. | Open main transformer (T1) pri- | 3. | Repair |
|
| mary or secondary circuit. |
|
|
| 4. | Defective Control PC Board. | 4. | Replace. See Procedure for |
|
|
|
| Replacing PC Boards. |
| 5. | Primary or secondary ther- | 5. | Amber thermal protection light is |
|
| mostats open. |
| on: Check for overheating; make |
|
|
|
| sure fan is operating and there is |
|
|
|
| no obstruction to free air flow. |
|
|
|
| |
Machine has minimum output and | 1. Terminals 75, 76, or 77 grounded | 1. | Check 75, 76, or 77 for ground to | |
no control. |
| to positive output. |
| positive output circuit. Nearly |
|
|
|
| zero ohms to ground indicates a |
|
|
|
| grounded circuit. A value greater |
|
|
|
| than a few thousand ohms is nor- |
|
|
|
| mal. |
|
|
|
| Board automatically reset within |
|
|
|
| a few seconds after ground is |
|
|
|
| cleared. |
|
|
|
| |
Machine has high output and no | 1. Terminals 75, 76, or 77 grounded | 1. | Check 75, 76, or 77 for ground to | |
control. |
| to negative output. |
| negative output circuit. Nearly |
|
|
|
| zero ohms to ground indicates a |
|
|
|
| grounded circuit. A value greater |
|
|
|
| than a few thousand ohms is nor- |
|
|
|
| mal. |
|
|
|
| Board automatically reset within |
|
|
|
| a few seconds after ground is |
|
|
|
| cleared. |
|
|
|
|
|
– 23 –