Lincoln Electric IM481-B Operating Instructions, Power Source Operation, Duty Cycle Amps Volts

Page 19

OPERATING INSTRUCTIONS

Safety Precautions

WARNING

ELECTRIC SHOCK can kill.

Have an electrician install and service this equipment.

Turn the input power off at the fuse box before working on equipment.

Do not touch electrically hot parts.

This next section applies to CV 500-I’s without the Capacitor Discharge Option:

---------------------------------------------------------------------

When using a CV 500-I power source with wire feed- ers, there will be a small spark if the electrode con- tacts the work or ground within several seconds after releasing the trigger.

When used with some wire feeders with the electrical trigger interlock in the ON position, the arc can restart if the electrode touches the work or ground during these several seconds.

POWER SOURCE OPERATION

Duty Cycle and Time Period

The CV 500-I is rated at the following duty cycles:

Duty Cycle*

Amps

Volts

 

 

 

100%

400

36

60%

450

38

50%

500

40

 

 

 

*Based upon a 10 minute time period. (i.e., for 60% duty cycle, it is 6 minutes on and 4 minutes off).

Overloading the power source may result in opening of an internal protective thermostat as indicated by the amber thermal protection light turning on.

STARTING THE MACHINE

The POWER toggle switch at the extreme right side of the control panel in the “ I “ position energizes and closes the three phase input contactor from a 115 volt auxiliary transformer. This in turn energizes the main power transformer.

The machine is de-energized when the POWER switch is in the “0” position.

The white light next to the POWER switch indicates when the input contactor is energized.

CONTROL SETTINGS & DESCRIPTIONS

OUTPUT VOLTAGE CONTROL DIAL

The Output control dial at the right of the control panel is a continuous control of the machine output voltage. The control may be rotated between minimum and maximum to adjust the machine output, even while welding.

The machine is equipped with line voltage compensa- tion as a standard feature. This will hold the output constant except at maximum output of the machine, through a fluctuation of ±10% input line voltage.

19

Image 19
Contents IM481-B Safety Depends on YouSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Output Control Dial Meanings of Graphic SymbolsPower ON-OFF Switch Output Control LOCAL-REMOTE SwitchCircuit Breaker Voltmeter SwitchThermal Protection Light Degree of protection provided by the enclosure Rating PlateSignifying the Chassis Ground Connection Earth Ground ConnectionSignifying the Earth Ground Connection Chassis Ground ConnectionDesign Summary Operational Features & ControlsGeneral Machine Description Recommended Processes & EquipmentCase Features Auxiliary Power ConnectionsRemote Control Connections WATER COOLER CONNECTORParalleling Machine & Circuit Protection Thermal Protection LightMETER OPTION Technical Specifications FALLING EQUIPMENT can cause InstallationSafety Precautions Input Power ConnectionsElectric Shock can kill Installation of Field Installed OptionsOutput Cable Connections Output CablesUndercarriages K817P, K841 Wire Feeder Control Cable ConnectionsConnection of CV 500-I to LN-22 or LN-25 Duty Cycle Amps Volts Power Source OperationSafety Precautions ELECTRIC SHOCK can kill Operating InstructionsPIN LEAD NO Function Front View of 14-PIN Connector ReceptacleTerminal Strip Connections Routine Maintenance VAC Auxiliary Power for Water CoolerMachine and Circuit Protection HOW to USE Troubleshooting Guide TroubleshootingTrouble Cause What To Do TROUBLESHOOTING GUIDEFaulty Output Control potentiometer Trouble Cause What To Do Output Voltage Connecting the Remote Control to the MachineFault Protection Operation Power I/O Switch CheckPower Silicon Controlled Rectifier Test Remote Control CheckPower Rectifier Bridge Assembly Checking Procedure Power Diode TestRubber Boot To plug To T1 main transformer Gate leads plug to Control P.C. boardEnhanced Diagram Page Page Precaucion Warnung