D-2

MAINTENANCE

D-2

 

 

 

GUN AND CABLE

MAINTENANCE

FOR MAGNUM™ 100L GUN

Gun Cable Cleaning

Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using low pressure air, gently blow out the cable liner from the gas diffuser end.

CAUTION

Excessive pressure at the start may cause the dirt to form a plug.

Flex the cable over its entire length and again blow out the cable. Repeat this procedure until no further dirt comes out.

Contact Tips, Nozzles, and Gun Tubes

1.Dirt can accumulate in the contact tip hole and restrict wire feeding. After each spool of wire is used, remove the contact tip and clean it by push- ing a short piece of wire through the tip repeatedly. Use the wire as a reamer to remove dirt that may be adhering to the wall of the hole through the tip.

2.Replace worn contact tips as required. A variable or huntingarc is a typical symptom of a worn con- tact tip. To install a new tip, choose the correct size contact tip for the electrode being used (wire size is stenciled on the side of the contact tip) and screw it snugly into the gas diffuser.

3.Remove spatter from inside of gas nozzle and from tip after each 10 minutes of arc time or as required.

4.Be sure the gas nozzle is fully screwed onto the

diffuser for gas shielded processes. For the Innershield® process, the gasless nozzle should be screwed onto the diffuser.

5.To remove gun tube from gun, remove gas nozzle or gasless nozzle and remove diffuser from gun tube. Remove both collars from each end of the gun handle and separate the handle halves. Loosen the locking nut holding the gun tube in place against the gun end cable connector. Unscrew gun tube from cable connector. To install gun tube, screw the locking nut on the gun tube as far as possible. Then screw the gun tube into the cable connector until it bottoms. Then unscrew (no more than one turn) the gun tube until its axis is perpendicular to the flat sides of the cable connec- tor and pointed in the direction of the trigger. Tighten the locking nut so as to maintain the proper relationship between the gun tube and the cable connector. Replace the gun handle, trigger and dif- fuser. Replace the gas nozzle or gasless nozzle.

CONFIGURATION OF COMPONENTS IN WIRE FEEDING SYSTEM

 

Contact Tip

Cable Liner

Drive Roll

 

 

 

 

Components shipped with

S19726-3

M16291-6

KP665-035

WELD-PAK 3200HD

.035(0.9mm)

.035(0.9mm)

2 Smooth grooves

 

 

 

Small .023-.025 (0.6mm)

 

 

 

Large .030(0.8mm)

 

 

 

 

K664-2 .035 (0.9mm)

S24221-1

M18971-1

M19631

Aluminum or Stainless Kit*

.035A (0.9mm)

.035(0.9mm)

 

 

 

 

 

F0r 0.025 wire feeding use the included S19726-1 contact tip.

If .030 Solid wire feeding is desired obtain an S19726-2 Contact Tip.

*It is important when changing between welding with steel wire and aluminum to exchange feeding components due to the lubricant applied to steel wire. Failure to do so may result in contaminated welds when welding aluminum.

WELD-PAK 3200HD

Image 36
Contents WELD-PAK 3200HD Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Please Examine Carton and Equipment For Damage ImmediatelyMaster Table of Contents for ALL Sections Installation Technical Specifications WELD-PAK 3200HDSafety Precautions Identify and Locate ComponentsElectric Shock can kill Work Clamp Installation Select Suitable LocationOutput Connections StackingGUN Installation Work Cable InstallationConnecting Gun Cable to the WELD-PAK GAS ConnectionFigure A.5 Input Connections Code Requirements for Input ConnectionsRequirements For Rated Output Undercarriage Assembly Figure A.7 WELD-PAK 3200HDDesign Features OperationGeneral Description Recommended ProcessesControls and Settings Welding CapabilityLimitations Wire Loading Welding OperationsSequence of Operation Friction Brake Adjustment Wire ThreadingCleaning Tip And Nozzle Process GuidelinesMaking a Weld Changing Machine Over to Feed Other Wire Sizes Welding with Gmaw MIGOverload Protection Learning to Weld Learning to WeldARC-WELDING Circuit SELF-SHIELDED Fcaw Welding ARCGmaw MIG Welding ARC Process SelectionCommon Metals Joint Types and PositionsFor Gmaw MIG Process For Fcaw Innershield ProcessWelding In The Vertical Position PenetrationFillet Welds Machine SET UP for the SELF-SHIELDED Fcaw Process Welding Techniques for the SELF- Shielded Fcaw ProcessVertical-down Welding Correct Welding PositionCorrect Electrical Stickout ESO Correct Welding SpeedHelpful Hints PracticeMachine SET UP for the Gmaw MIG Process Welding Techniques for the Gmaw MIG ProcessFor the WELD-PAK 3200HD, use the following Troubleshooting Welds To Eliminate a Ropy Convex Bead in order of importanceTo Correct Poor Penetration in order of impor- tance To Eliminate Stubbing* in order of importanceProper Gun Handling Application Chart Accessories Optional AccessoriesK586-1 Deluxe Adjustable Gas Regulator Hose Kit Replacement Parts Maintenance Maintenance Safety PrecautionsRoutine Maintenance GUN and Cable Maintenance Configuration of Components in Wire Feeding SystemFor Magnum 100L GUN Contact Tip Cable Liner Drive RollComponent Replacement Procedures Changing the Contact TIPChanging Drive Roll Changing Liner GUN Handle PartsLiner trim length Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Recommended Course of ActionContact your local Lincoln Authorized Field Service FacilityWelding Problems Diagrams WELD-PAK 3200HD Wiring DiagramWELD-PAK 3200HD How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung