Lincoln Electric IM595-A Installation, Technical Specifications PRO-CUT, Three Phase Single Phase

Page 9

 

A-1

 

 

INSTALLATION

 

 

A-1

 

TECHNICAL SPECIFICATIONS - PRO-CUT 80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE PHASE

 

 

 

 

SINGLE PHASE

 

 

 

 

Standard

 

Input Current

 

 

 

Standard

 

Input Current

 

 

 

 

Voltage

 

at Rated Output

Model

 

 

Voltage

at Rated Output

Model

 

 

 

208/230/460

 

48/44/25

50/60 Hz

 

 

208/230/460

 

87/81/48

50/60Hz

 

 

 

200/380-415

 

46/27/24

50/60 Hz

 

 

 

 

 

 

 

 

 

460/575

 

25/20

50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

Duty Cycle

60% Duty Cycle

100% Duty Cycle

Current

Range

35-85 Amps

AMPS

80

60

OUTPUT

Open Circuit

Voltage

MAX

335 VDC

VOLTS

140

130

Pilot Current

20 Amps @ 100% Duty Cycle

REQUIRED GAS FLOW RATE

70 PSI @ 480 SCFH

( 4.8 Bar. @ 13550 LHR)

REQUIRED GAS INLET PRESSURE

80 to 120 PSI

( 5.4 Bar. to 8.1 Bar.)

RECOMMEND INPUT WIRE AND FUSE SIZES

For all plasma cutting applications Based on U.S. National Electrical Code

Ambient Temperature 30oC or Less

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

THREE PHASE

 

 

 

SINGLE PHASE

 

 

 

 

 

Type 75°C

 

 

 

 

Type 75°C

 

 

 

Type 75°C

Copper

 

 

 

Type 75°C

Copper

 

 

Fuse

Copper

Ground

 

 

Fuse

Copper

Ground

 

 

(Superlag)

Wire in

Wire in

 

 

(Superlag)

Wire in

Wire in

 

Input

or

Conduit

Conduit

 

Input

or

Conduit

Conduit

 

Voltage

Breaker

AWG (IEC)

AWG (IEC)

 

Voltage

Breaker

AWG (IEC)

AWG (IEC)

 

Frequency(1)

Size

Sizes

Sizes

 

Frequency(1)

Size

Sizes

Sizes

 

 

 

 

 

 

 

 

 

 

 

200/50/60

60

8 (8.4mm2)

8 (8.4mm2)

 

208/50/60

100

4 (21.1mm2)

4 (21.1mm2)

 

208/50/60

60

8 (8.4mm2)

8 (8.4mm2)

 

230/50/60

100

4 (21.1mm2)

4 (21.1mm2)

 

230/50/60

60

8 (8.4mm2)

8 (8.4mm2)

 

460/50/60

60

8 (8.4mm2)

8 (8.4mm2)

 

380-415/50/60

40

10 (6mm2)

10 (6mm2)

 

 

 

 

 

 

460/50/60

40

10 (6mm2)

10 (6mm2)

 

 

 

 

 

 

575/50/60

30

10 (6mm2)

10 (6mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

16.5in. 419 mm

PHYSICAL DIMENSIONS

Width

Depth

13.75 in.

29.5 in.

349 mm

749 mm

Weight

Including Machine, Torch and

Torch Cable (Length)

(25ft/7.6m) (50ft/15.2m)

98 lbs. 113 lbs.

44.5 kg. 51.4 kg.

(1) Input voltage must be within ±10% of rated value.

Image 9
Contents PRO-CUTTM80 Plasma Cutting or Gouging can be hazardous SafetyPlasma ARC can injure Page Sûreté Pour Soudage a L’Arc Précautions DE Sûreté Thank You Table of Contents Section E Section DSection F P340, P210-K SeriesInstallation Technical Specifications PRO-CUTThree Phase Single Phase Safety Precautions Electric Shock can Kill Select Proper LocationHigh Frequency Interference Protection Three Phase Power Input CONNEC- Tion for the PRO-CUT Input Power Cord Connector InstallationInput Electrical Connections USE on Engine Driven Power Supplies Input Voltage Reconnection ProcedureInput Power Restrictions Frame GroundingOutput Connections GAS Input ConnectionsPreheat Temperature for Plasma Cutting Safety PrecautionsOperation DescriptionDesign Features Advantages Operational Features and ControlsUser Responsibility Recommended Processes and EquipmentConsumable Life Cutting CapabilityGAS Pressure Settings Controls and SettingsLimitations Prepare to CUTDo not use pliers or over tighten Electric Shock can KillPilot ARC Discussion Procedure RecommendationsOutput set below 45 Amps Output set above 45 AmpsARC Start Machine InterfaceARC Initiated ARC VoltageGeneral Options Accessories AccessoriesInput Filter Capacitor Discharge Procedure MaintenancePeriodic Maintenance Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingImmediately Activated. Remove Input powerYour local Lincoln Authorized Field Service Facility Possible fault in Output Power board Or dross Symptom Check Your local Lincoln Authorized Field Service FacilityDiagrams Wiring Diagram PRO-CUT 80 Codes 10573, 10574, 10577Wiring Diagram PRO-CUT 80 Codes 10575 Wiring Diagram for Codes 11019, 11020, 11023 Wiring Diagram for Codes 11021 Dimension Print PRO-CUT PRO-CUT Precaucion Warnung