OPERATION | ||
|
|
|
“ | RANGE” SWITCH |
|
The “Range” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding.
Process | Range Setting |
| Current Range |
|
|
|
|
|
|
|
|
STICK/TIG | 90 Max. |
| 40 to 90 Amps |
(Constant current) | 145 Max. |
| 70 to 145 Amps |
(3 range settings) | 225 MAX. |
| 120 to 225 Amps |
|
|
|
|
|
|
|
|
CAUTION
Never change the “RANGE” Switch setting while welding. This will damage the switch.
“CONTROL” DIAL
Provides a fine welding current adjustment within the Range Switch settings in the STICK mode and weld- ing voltage control with the Range switch set in the wire feed mode.
EAGLE™ 10,000 PLUS APPROXIMATE FUEL CONSUMPTION
| KOHLER |
| 23 H.P. COMMAND CH23S |
|
|
Low Idle - No Load | .40 Gallons/Hour |
2400 RPM | (1.50 Liters/Hour) |
High Idle - No Load | .7 Gallons/Hour |
3700 RPM | (2.8 Liters/Hour) |
DC CC Weld Output | 1.3 Gallons/Hour |
210 Amps @ 25 Volts | (4.9 Liters/Hour) |
|
|
Auxiliary Power | 1.4 Gallons/Hour) |
9000 Watts | (5.3 Liters/Hour) |
|
|
EAGLE™ 10,000 PLUS