Lincoln Electric IM10028-B manual General Description, Welder Controls Function and Operation

Page 17

B-1

OPERATION

B-1

 

 

 

SAFETY PRECAUTIONS

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

Always operate the welder with the hinged door closed and the side panels in place.

Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.

------------------------------------------------------------------------

GENERAL DESCRIPTION

The EAGLE™ 10,000 Plus is a twin-cylinder, gasoline driven, multiprocess arc welder and AC power gener- ator. It is built in a heavy gauge steel case for durabili- ty on the job site.

Codes 11791 and above meet EPA evaporative emis- sion requirements.

WELDER CONTROLS - FUNCTION AND OPERATION

ENGINE SWITCH

The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine.

When placed in the “OFF” position, the ignition circuit is de-energized to shut down the engine.

When held in the “START” position, the engine starter motor is energized.

When in “HIGH IDLE” (

) position, the engine will

run continuously at high idle.

 

 

When in “AUTO IDLE” (

/

) position, the

engine will run continuously and the idler operates as follows:

Welding

When the electrode touches the work, the weld- ing Arc is initiated and the engine accelerates to full Speed.

After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds.

Auxiliary Power

With the engine running at low idle and auxiliary power for lights or tools are drawn (approximate- ly 100-150 watts or greater) from the recepta- cles, the engine will accelerate to high speed.  If no power is being drawn from the receptacles (and not welding) for 10-14 seconds, the idler reduces the engine speed to low idle.

EAGLE™ 10,000 PLUS

Image 17
Contents Eagle 10,000 Plus Safety Depends on YouCalifornia Proposition 65 Warnings SafetySafety Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté IvSAFETYThank You Table of Contents Installation Machine Grounding Safety PrecautionsSpark Arrester TowingBattery Connections PRE-OPERATION ServiceGasoline Fuel only GasolineWelding Output Cables Additional Safety PrecautionTotal Combined Length of Electrode and Work Cables Angle of OperationInstructions Additional Safety PrecautionsLocation / Ventilation StackingWelder Operation Auxiliary PowerDevices Without Addi Tional Resistive Type Loads Standby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Eagle 10,000 Plus to Premises Wiring Operation Engine SwitchGENERAL DESCRIPTION Welder Controls Function and Operation23 H.P. Command CH23S Range SwitchEagle 10,000 Plus Approximate Fuel Consumption Control DialBREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineTypical Current Ranges 1 for Tungsten ELECTRODES2 Welding ProcessStick Constant Current Welding Scratch Start TIG Constant Current WeldingARC Gouging 5OPERATIONB-5K1745-1 Welding GAS Cylinder LOX Tank Holder AccessoriesStick RECOMMENDED EQUIPMENTTIG K1783-4 TIG TorchSafety Precautions MaintenanceRoutine Maintenance Engine OIL ChangeOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Diagrams M22195 Dimension PrintEagle 10,000 Plus Eagle 10,000 Plus Precaucion Warnung