B-5 OPERATIONB-5
ARC GOUGING
The EAGLE™ 10,000 Plus can be used for limited arc gouging.
Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:
|
| ELECTRODE SETTING | CURRENT RANGE (DC, electrode positive) |
| |||
|
|
|
|
|
|
|
|
|
| 1/8 |
|
| 30 - 60 Amps |
|
|
|
| 5/32 |
|
| 90 - 150 Amps |
|
|
|
| 3/16 |
|
| 150 - 250 Amps |
|
|
|
|
|
|
|
|
|
|
|
| SUMMARY OF WELDING PROCESSES |
|
| |||
|
|
|
|
|
|
|
|
|
| CONTROL |
|
| ELECTRODE |
|
|
|
| CABLE |
| IDLE | WHEN NOT |
| TO START |
PROCESS | USED |
| MODE | WELDING |
| WELDING | |
|
|
|
|
|
|
|
|
STICK | No |
| AUTO | Hot | Touch electrode to work. | ||
|
|
|
|
|
| Welding starts immediately | |
|
|
|
|
|
| And engine goes to high | |
|
|
|
|
|
| Idle. | |
|
|
|
|
|
| ||
TIG, TIG MODULE WITH | Yes |
| HIGH | Cold | Press Amptrol, | ||
WITH CONTACTOR KIT |
|
|
|
| Contactor closes, | ||
CONTROL CABLE, & |
|
|
|
| Welding starts immediately. | ||
AMPTROL |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EAGLE™ 10,000 PLUS