CONNECTION DIAGRAMS | ||||
RANGER 300 DLX TO K867 CONTROL CABLE ADAPTER CONNECTION DIAGRAM |
| |||
| WARNING |
| ||
| Do not operate with panels open. |
| Keep guards in place. |
|
| Disconnect NEGATIVE | Keep away from moving parts. |
| |
| before servicing. |
| Only qualified personnel should install,use |
|
| Do not touch electrically live parts. |
| or service this equipment. |
|
14 PIN |
|
| N.C. |
|
AMPHENOL |
|
| ||
81 |
|
| ||
|
|
|
| |
|
| 82 | NOT USED ON RANGER POWER SOURCES |
|
|
| SPARE |
|
|
| K867 UNIVERSAL | 2 | CONNECT TOGETHER FOR |
|
| ADAPTER PLUG | 4 | N.D. |
|
|
| 41 | WELDING OUTPUT |
|
|
| 42 VAC |
| |
|
| 42 |
| |
|
| N.E. |
| |
|
| 31 |
| |
|
| 115 VAC |
| |
|
| 32 |
| |
TO WORK | ELECTRODE |
|
| |
GND | POWER SOURCE FRAME CONNECTION |
| ||
|
|
| ||
| ELECTRODE CABLE | 21 | WIRE FEEDER VOLTMETER CONNECTION |
|
|
| CONNECTS TO (WORK TERMINAL) OF POWER SOURCE |
| |
| TO WIRE FEED UNIT | 77 | 10K |
|
| TO WORK | 76 | REMOTE OUTPUT CONTROL |
|
| 75 | MIN. |
|
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE RANGE SWITCH TO A WIRE
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION | TO |
| 2 |
| |||
|
| ||
K867 |
|
| |
RELAY TO CLOSE LEADS 2 & 4. |
| 4 | |
|
|
|
N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.
TO WIRE FEEDER
RANGER 300 DLX /
WARNING
Do not operate with panels open.
Disconnect NEGATIVE
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use or service this equipment.
115V RECEPTACLE | |
RANGER |
|
14 PIN WIRE FEEDER | |
RECEPTACLE |
|
TO WORK | ELECTRODE |
K488 SG
CONTROL MODULE
SPOOL GUN
6 PIN REMOTE | |
RECEPTACLE | INPUT CABLE |
ELECTRODE CABLE
TO WORK TO CONTROL MODULE
CAUTION : BE SURE THAT CONTROL MODULE MODE SLIDE SWITCH IS IN THE "LINCOLN" (CONTACT CLOSURE) POSITION BEFORE ATTEMPTING TO OPERATE CONTROL MODULE. INCORRECT SWITCH POSITION COULD RESULT IN DAMAGE TO THE CONTROL MODULE AND/OR POWER SOURCE.
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE
N.C. IF OPTIONAL K857 REMOTE OUTPUT CONTROL IS CONNECTED TO 6 PIN RECEPTACLE,PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.
N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.