Craftsman 919.724701 owner manual Air Filter Inspection and Replacement, Motor

Page 17

6.After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.

Air Filter - Inspection and Replacement

Risk of Burns. Hot surfaces.

Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing.

A dirty air filter will not allow the compressor to operate at full capacity. Keep the air filter clean at all times.

1.Remove the air filter and make sure it is clean.

Air Filter

IMPORTANT: Do not operate the compressor with the air filter removed.

2.If dirty, rinse air filter with warm water and squeeze dry.

3.Replace air filter.

NOTE: If the air filter is extremely dirty it will need to be replaced. Refer to the “Repair Parts” for the correct part number.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves.

Motor

The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

If the overload protector shuts the motor off frequently, check for a possible voltage problem. Low voltage can also be suspected when:

1.The motor does not get up to full power or speed.

2.Fuses blow out when starting the motor; lights dim and remain dim when motor is started and is running.

17- ENG

D27610

Image 17
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions What Could Happen HazardWhat can Happen Hazard Belt can cause serious injury if they Result in serious burnsNever operate the compressor with When Transporting Compressor Accessories AccessoriesGlossary Duty CycleAssembly Plug Grounded Outlets Grounding Pin InstallationLocation of the Air Compressor Voltage and Circuit Protection Extension CordsDescription of Operation OperationOutlet Pressure Gauge The outlet Tank Pressure Gauge The tankBreak-in Procedure How to Use Your UnitHow to Start To Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection and ReplacementMotor Air FilterTo Replace or Clean Check Valve Service and AdjustmentsRing Nut Outlet Tube Pressure Relief Check ValveRegulator Arrow To Replace RegulatorRegulator Tank Outlet Pressure PressureGauge Quick Connect Storage Troubleshooting Pressure reading Check wiring connection Sears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresConsignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Avertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesAvertissement Risque de projection dobjets Avertissement Risque déclatementRisque Prévention Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque de chute Avertissement Risque de brûluresAvertissement Risque relié aux pièces mobiles Avertissement Risque dune utilisation dangereuse RisqueCycle DE Service AccessoiresAccessoires LexiqueAssemblage Terre inappropriée peut entraîner des chocs électriques Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Avant le démarrage Utilisation de lappareilArrêt de lappareil Procédures de rodageMise en marche Avant chaque mise en marcheResponsabilités du client EntretienVérification de la soupape de sûreté Vidange du réservoirMoteur Filtre à air Inspection et remplacementRisque de brûlures Filtre à airEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenueRégulateur Flèche Remplacement du régulateurRisque déclatement RangementSerrer DépannageDéclatement.Ne pas percer ExploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D27610 Get it fixed, at your home or ours