Craftsman 919.724701 owner manual To Replace Regulator, Regulator Arrow

Page 19

11.Replace the pressure release tube. Tighten nuts.

12.Replace the outlet tube and tighten nuts.

13.Replace shrouds and console.

14.Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Unplug unit.

3.Remove the regulator ring and remove the console cover. gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

Regulator

Cover

Ring

 

4.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch.

5.Using an adjustable wrench, rotate the pressure switch assembly as shown.

Regulator Tank

Outlet Pressure

PressureGauge

Gauge

Quick

Connect

6.Remove the outlet pressure gauge, tank pressure gauge, and quick connect (if equipped) from the regulator.

7.Remove the regulator.

8.Apply pipe sealant tape to the nipple.

9.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Regulator

Arrow

10.Reapply pipe sealant to outlet pressure gauge, tank pressure gauge, and quick connect.

11.Reassemble outlet pressure gauge, tank pressure gauge, and quick connect. Orient outlet pressure gauge and tank pressure gauge to read correctly. Tighten quick connect with wrench.

12.Rotate pressure switch assemble into correct position.

13.Replace console cover and regulator ring.

19- ENG

D27610

Image 19
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions What Could Happen HazardWhat can Happen Hazard Never operate the compressor with Result in serious burnsBelt can cause serious injury if they When Transporting Compressor Duty Cycle AccessoriesAccessories GlossaryAssembly Location of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Voltage and Circuit Protection Extension CordsTank Pressure Gauge The tank OperationDescription of Operation Outlet Pressure Gauge The outletBreak-in Procedure How to Use Your UnitHow to Start To Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Filter Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves MotorNut Outlet Tube Pressure Relief Check Valve Service and AdjustmentsTo Replace or Clean Check Valve RingRegulator Tank Outlet Pressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Pressure reading Check wiring connection Sears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresMesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Avertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Avertissement Risque dune utilisation dangereuse RisqueLexique AccessoiresCycle DE Service AccessoiresAssemblage Terre inappropriée peut entraîner des chocs électriques Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Procédures de rodage Utilisation de lappareilAvant le démarrage Arrêt de lappareilMise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéFiltre à air Filtre à air Inspection et remplacementMoteur Risque de brûluresEntretien ET Réglages Remplacement ou nettoyage de la soupape de retenueRégulateur Flèche Remplacement du régulateurRisque déclatement RangementExploser DépannageSerrer Déclatement.Ne pas percerConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D27610 Get it fixed, at your home or ours