Craftsman 919.724701 owner manual Pressure reading

Page 22

PROBLEM

CAUSE

CORRECTION

Pressure reading

It is normal for "some"

If there is an excessive

on the regulated

pressure drop to occur.

amount of pressure drop

pressure gauge

 

when the accessory is used,

drops when an

 

adjust the regulator following

accessory is

 

the instructions in the

used.

 

"Description of Operation"

 

 

paragraph in the “Operation

 

 

Section.

 

 

NOTE: Adjust the regulated

 

 

pressure under flow

 

 

conditions (while accessory

 

 

is being used).

Knocking Noise.

Possible defect in safety

Operate safety valve

 

valve.

manually by pulling on ring.

 

 

If valve still leaks, it should

 

 

be replaced.

 

Defective check valve.

Remove and clean, or

 

 

replace.

 

 

 

Compressor is

Prolonged excessive use of

Decrease amount of air

not supplying

air.

usage.

enough air to

Compressor is not large

Check the accessory air

operate

accessories.

enough for air requirement.

requirement. If it is higher

 

 

than the SCFM or pressure

 

 

supplied by your air

 

 

compressor, you need a

 

 

larger compressor.

 

Hole in hose.

Check and replace if

 

 

required.

 

Check valve restricted.

Remove and clean, or

 

 

replace.

 

Air leaks.

Tighten fittings.

 

Restricted air intake filter.

Clean or replace air intake

 

 

filter. Do not operate the air

 

 

compressor with the filter

 

 

removed. Refer to the "Air

 

 

Filter" paragraph in the

 

 

"Maintenance" section.

 

 

 

Regulator knob

Damaged regulator.

Replace.

has continuous

 

 

air leak.

 

 

 

 

 

D27610

22- ENG

Image 22
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Hazard What Could HappenWhat can Happen Hazard Never operate the compressor with Result in serious burnsBelt can cause serious injury if they When Transporting Compressor Glossary AccessoriesAccessories Duty CycleAssembly Location of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Extension Cords Voltage and Circuit ProtectionOutlet Pressure Gauge The outlet OperationDescription of Operation Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureHow to Start Customer Responsibilities MaintenanceTo Check Safety Valve To Drain TankMotor Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves Air FilterRing Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveRegulator Tank Outlet Pressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Pressure reading Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Mesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires AccessoiresCycle DE Service LexiqueAssemblage Emplacement du compresseur dair Terre inappropriée peut entraîner des chocs électriquesRallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Arrêt de lappareil Utilisation de lappareilAvant le démarrage Procédures de rodageAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirRisque de brûlures Filtre à air Inspection et remplacementMoteur Filtre à airRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Risque déclatementDéclatement.Ne pas percer DépannageSerrer ExploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D27610 Get it fixed, at your home or ours