IMPORTANT SAFETY INSTRUCTIONS

Save these instructions

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.

HAZARD

WARNING: Risk of explosion or fire

What Could Happen

It is normal for electrical contacts within the motor and pressure switch to spark.

If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion.

Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire.

Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended.

How To Prevent It

Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors.

If spraying flammable materials, locate compressor at least 20 feet away from spray area. An additional length of hose may be required.

Store flammable materials in a secure location away from compressor.

Never place objects against or on top of compressor. Operate compressor in an open area at least 12 inches away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.

Operate compressor in a clean, dry well ventilated area. Do not operate unit indoors or in any confined area.

Always remain in attendance with the product when it is operating.

Always disconnect electrical power by moving pressure switch lever to the off position and drain tank daily or after each use.

D27610

4- ENG

Image 4 Contents
AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Hazard What Could HappenWhat can Happen Hazard Never operate the compressor with Result in serious burnsBelt can cause serious injury if they When Transporting Compressor Accessories AccessoriesGlossary Duty CycleAssembly Location of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Extension Cords Voltage and Circuit ProtectionOperation Description of OperationOutlet Pressure Gauge The outlet Tank Pressure Gauge The tankHow to Use Your Unit Break-in ProcedureHow to Start Maintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Filter Inspection and Replacement Air Compressor Pump Intake and Exhaust ValvesMotor Air FilterService and Adjustments To Replace or Clean Check ValveRing Nut Outlet Tube Pressure Relief Check ValveRegulator Tank Outlet Pressure PressureGauge Quick Connect To Replace RegulatorRegulator Arrow Storage Troubleshooting Pressure reading Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Mesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires Cycle DE ServiceAccessoires LexiqueAssemblage Emplacement du compresseur dair Terre inappropriée peut entraîner des chocs électriquesRallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Utilisation de lappareil Avant le démarrageArrêt de lappareil Procédures de rodageAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirFiltre à air Inspection et remplacement MoteurRisque de brûlures Filtre à airRemplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur FlècheRangement Risque déclatementDépannage SerrerDéclatement.Ne pas percer ExploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D27610 Get it fixed, at your home or ours