Craftsman 919.7255 manual Check wiring connection

Page 23

PROBLEM

CAUSE

CORRECTION

Regulator will

Damaged regulator

Replace

not shut off air

 

 

outlet.

 

 

 

 

 

Motor will not

Motor overload protection

Let motor cool off and

run.

switch has tripped

overload switch will

 

 

automatically reset.

 

Tank pressure exceeds

Motor will start automatically

 

pressure switch “cut-in”

when tank pressure drops

 

pressure.

below “cut-in” pressure of

 

 

pressure switch.

 

Extension cord is wrong

Check for proper gauge wire

 

length or gauge.

and cord length.

 

Check valve stuck open.

Remove and clean, or

 

 

replace.

 

Loose electrical connections.

Check wiring connection

 

 

inside pressure switch and

 

 

terminal box area.

 

Possible defective motor or

Have checked by a Trained

 

starting capacitor.

Service Technician.

 

Paint spray on internal motor

Have checked by a Trained

 

parts.

Service Technician. Do not

 

 

operate the compressor in

 

 

the paint spray area. See

 

 

flammable vapor warning.

 

Pressure release valve on

Bleed the line by pushing the

 

pressure switch has not

lever on the pressure switch

 

unloaded head pressure.

to the “off” position; if the

 

 

valve does not open, replace

 

 

switch.

 

Fuse blown, circuit breaker

1. Check fuse box for blown

 

tripped.

fuse and replace as

 

 

necessary. Reset circuit

 

 

breaker. Do not use a fuse

 

 

or circuit breaker with

 

 

higher rating than that

 

 

specified for your particular

 

 

branch circuit.

 

 

2. Check for proper fuse. You

 

 

should use a time delay

 

 

fuse.

 

 

3. Check for low voltage

 

 

conditions and/or proper

 

 

extension cord.

 

 

4. Disconnect the other

 

 

electrical appliances from

 

 

circuit or operate the

 

 

compressor on its own

 

 

branch circuit.

 

 

 

23- ENG

D24445

Image 23
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Model No 919-725500 Specification ChartSafety Guidelines Definitions Important Safety InstructionsRisk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk of Falling Risk of BurnsRisk from Moving Parts Risk of Unsafe Operation Glossary AccessoriesDuty Cycle AssemblyImproper Grounding can Result in Electrical Shock InstallationLocation of the Air Compressor Risk of ElectricalVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor Pressure Release Valve How to StopBefore Starting Check ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Filter Cover Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves MotorScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveRegulator Arrow To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect NippleStorage Problem Cause Correction TroubleshootingPressure reading Check wiring connection If calling locally, please use one of the following numbers Service and Repair PartsVendu par Sears Canada, Inc. Toronto, Ont. M5B 2B8 Guide de l’utilisateur Compresseur dairSears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresConsignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Risque Risque D’EXPLOSION OU D’INCENDIERisque DE Projection D’OBJETS Risque D’ÉCLATEMENTRisque PAR Inhalation Risque DE Choc ÉlectriqueRisque DE Chute Risque DE BrûluresRisque Relié AUX Pièces Mobiles Risque Dune Utilisation Dangereuse Lexique AccessoiresAssemblage Cycle DE ServiceDirectives DE Mise À LA Terre Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesDescription du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Avant le démarrage Utilisation de lappareilArrêt de lappareil Mise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéFiltre à air Filtre à air Inspection et remplacementMoteur Entretien ET Réglages Remplacement ou nettoyage de la soupape de retenueRégulateur Remplacement du régulateurMano- mètre de sortie Régulateur Raccord à connexion rapide EmboutRangement Peut éclater ou exploser DépannageProblème Cause Correction SerrerConsidérée normale Pas Surcharges déclenché Composez LE Pour Pièces DE Rechange ET Service DE Réparation