Craftsman 919.7243 Repairs attempted by unqualified, Accordance with national and local

Page 6

HAZARD

WARNING: Risk of Electrical Shock

 

What Could Happen

How To Prevent It

 

Your air compressor is powered by

Never operate the compressor outdoors

 

electricity. Like any other electrically

when it is raining or in wet conditions.

 

powered device, if it is not used

Never operate compressor with

 

properly it may cause electric shock.

 

protective covers removed or damaged.

 

 

 

 

 

 

 

Repairs attempted by unqualified

Any electrical wiring or repairs required

 

personnel can result in serious injury

on this product should be performed by

 

or death by electrocution.

authorized service center personnel in

 

 

accordance with national and local

 

 

electrical codes.

 

 

 

 

 

Electrical Grounding: Failure to provide

Make certain that the electrical circuit to

 

adequate grounding to this product

which the compressor is connected

 

could result in serious injury or death

provides proper electrical grounding,

 

from electrocution.

correct voltage and adequate fuse

 

See grounding instructions.

protection.

 

 

 

 

HAZARD

WARNING: Risk to Breathing

What Could Happen

How To Prevent It

The compressed air directly from your

Air obtained directly from the compressor

compressor is not safe for breathing.

should never be used to supply air for

The air stream may contain carbon

human consumption. In order to use air

monoxide, toxic vapors, or solid

produced by this compressor for

particles from the tank. Breathing these

breathing, suitable filters and in-line

contaminants can cause serious injury

safety equipment must be properly

or death.

installed. In-linefilters and safety

 

equipment used in conjunction with the

 

compressor must be capable of treating

 

air to all applicable local and federal

 

codes prior to human consumption.

 

 

Sprayed materials such as paint, paint

Work in an area with good cross

solvents, paint remover, insecticides,

ventilation. Read and follow the safety

weed killers, may contain harmful

instructions provided on the label or

vapors and poisons.

safety data sheets for the materials you

 

are spraying. Use a NIOSH/ MSHA

 

approved respirator designed for use with

 

your specific application.

 

 

D26700

6- ENG

Image 6
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions Location away from compressor Spray area. An additional length of hoseExplosion May be required Fire, do not allow the compressor toAttachments & Accessories Accordance with national and local Safety equipment must be properlyRepairs attempted by unqualified Electrical codesHot for several minutes after operation Or attempt maintenance until unit hasResult in serious burns Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Glossary AccessoriesAccessories Duty CycleTools Required for Assembly Assemble Wheels AssemblyContents of Carton UnpackingInstallation Location of the Air CompressorPlug Grounded Outlets Grounding Pin Extension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation Hose Wrap Conveniently stores up to 50 feet of air hose How to StopBefore First Start-up Hose WrapHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankAir Filter Inspection Replacement Air Compressor Pump Intake and Exhaust ValvesAir Filter Nut Outlet Tube Pressure Relief Check Valve Service and AdjustmentsTo Replace or Clean Check Valve Screwdriver Open position nothing is visibleNipple To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect Regulator ArrowStorage Troubleshooting Pressure reading Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Tableau DES Spécifications Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionAvertissement Risque déclatement Risque PréventionAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque de brûlures Avertissement Risque relié aux pièces mobilesAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires AccessoiresCycle DE Service LexiqueAssemblage Emplacement du compresseur dair Terre inappropriée peut entraîner des chocs électriquesRallonges Protection contre la surtension et protection du circuitUtilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Avant le démarrage Utilisation de lappareilArrêt de lappareil Dévidoir PourAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirFiltre à air Inspection et remplacement Filtre à airRemplacement ou nettoyage de la Soupape de retenue Entretien ET RéglagesEmbout Remplacement du régulateurRégulateur Raccord à connexion rapide RégulateurRangement Déclatement. Ne pas percer DépannageSerrer ExploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D26700 Get it fixed, at your home or ours