Craftsman 919.7243 Maintenance, Customer Responsibilities, To Check Safety Valve, To Drain Tank

Page 16

MAINTENANCE

Customer Responsibilities

 

Before

Daily or

Every

Every

 

 

each

after

Yearly

 

40

100

 

each

 

use

use

hours

hours

 

 

 

 

Check Safety Valve

 

 

 

 

Drain Tank

 

 

 

 

Air Filter

 

 

(1)

 

Air compressor pump intake

 

 

 

 

and exhaust valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1- more frequent in dusty or humid conditions

 

 

 

 

 

 

 

 

Risk of Unsafe

Operation. Unit

cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

Risk of Bursting. If the safety valve

does not work properly, over- pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

To Drain Tank

1.Set the On/Auto/Off lever to "OFF" and unplug unit.

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

5.Drain water from air tank by opening drain valve (counter- clockwise) on bottom of tank.

Risk of Bursting. Water will con-

dense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

D26700

16- ENG

Image 16
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Spray area. An additional length of hose Explosion May be requiredLocation away from compressor Fire, do not allow the compressor toAttachments & Accessories Safety equipment must be properly Repairs attempted by unqualifiedAccordance with national and local Electrical codesOr attempt maintenance until unit has Result in serious burnsHot for several minutes after operation Do not reach around protective shroudsFire, Inhalation, Damage to Vehicle Surfaces Accessories AccessoriesGlossary Duty CycleAssembly Contents of CartonTools Required for Assembly Assemble Wheels UnpackingLocation of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Extension Cords Voltage and Circuit ProtectionKnow Your Air Compressor OperationDescription of Operation How to Stop Before First Start-upHose Wrap Conveniently stores up to 50 feet of air hose Hose WrapHow to Start Before Each Start-UpMaintenance To Check Safety ValveCustomer Responsibilities To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection ReplacementAir Filter Service and Adjustments To Replace or Clean Check ValveNut Outlet Tube Pressure Relief Check Valve Screwdriver Open position nothing is visibleTo Replace Regulator Outlet Pressure Gauge Regulator Quick ConnectNipple Regulator ArrowStorage Troubleshooting Pressure reading Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Mesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalationAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires Cycle DE ServiceAccessoires LexiqueAssemblage Emplacement du compresseur dair Terre inappropriée peut entraîner des chocs électriquesRallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Utilisation de lappareil Arrêt de lappareilAvant le démarrage Dévidoir PourAvant chaque mise en marche Mise en marcheEntretien Responsabilités du clientVérification de la soupape de sûreté Vidange du réservoirFiltre à air Inspection et remplacement Filtre à airRemplacement ou nettoyage de la Soupape de retenue Entretien ET RéglagesRemplacement du régulateur Régulateur Raccord à connexion rapideEmbout RégulateurRangement Dépannage SerrerDéclatement. Ne pas percer ExploserConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D26700 Get it fixed, at your home or ours