Craftsman 919.7243 owner manual Result in serious burns, Hot for several minutes after operation

Page 7

HAZARD

WARNING: Risk of Burns

What Could Happen

How To Prevent It

Touching exposed metal such as the

Never touch any exposed metal parts

compressor head or outlet tubes, can

on compressor during or immediately

after operation. Compressor will remain

result in serious burns.

hot for several minutes after operation.

 

 

Do not reach around protective shrouds

 

or attempt maintenance until unit has

 

been allowed to cool.

 

 

HAZARD

WARNING: Risk from Moving Parts

What Could Happen

How To Prevent It

Moving parts such as the pulley, flywheel,

Never operate the compressor with

and belt can cause serious injury if they

guards or covers which are damaged or

come into contact with you or your

removed.

clothing.

 

 

 

Attempting to operate compressor with

Any repairs required on this product

damaged or missing parts or attempting

should be performed by authorized

to repair compressor with protective

service center personnel.

shrouds removed can expose you to

 

moving parts and can result in serious

 

injury.

 

 

 

HAZARD

WARNING: Risk of Falling

What Could Happen

A portable compressor can fall from a table, workbench, or roof causing damage to the compressor and could result in serious injury or death to the operator.

How To Prevent It

Always operate compressor in a stable secure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations.

7- ENG

D26700

Image 7
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Fire, do not allow the compressor to Spray area. An additional length of hoseExplosion May be required Location away from compressorAttachments & Accessories Electrical codes Safety equipment must be properlyRepairs attempted by unqualified Accordance with national and localDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationFire, Inhalation, Damage to Vehicle Surfaces Duty Cycle AccessoriesAccessories GlossaryUnpacking AssemblyContents of Carton Tools Required for Assembly Assemble WheelsLocation of the Air Compressor InstallationPlug Grounded Outlets Grounding Pin Voltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Hose Wrap How to StopBefore First Start-up Hose Wrap Conveniently stores up to 50 feet of air hoseBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection ReplacementAir Filter Screwdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveRegulator Arrow To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect NippleStorage Troubleshooting Pressure reading Check wiring connection Sears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresMesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Avertissement Risque dexplosion ou dincendie Prévention Conserver ces directivesRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque par inhalation Avertissement Risque de choc électriqueAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Avertissement Risque dune utilisation dangereuse RisqueLexique AccessoiresCycle DE Service AccessoiresAssemblage Terre inappropriée peut entraîner des chocs électriques Emplacement du compresseur dairProtection contre la surtension et protection du circuit RallongesFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Dévidoir Pour Utilisation de lappareilArrêt de lappareil Avant le démarrageMise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéFiltre à air Filtre à air Inspection et remplacementEntretien ET Réglages Remplacement ou nettoyage de la Soupape de retenueRégulateur Remplacement du régulateurRégulateur Raccord à connexion rapide EmboutRangement Exploser DépannageSerrer Déclatement. Ne pas percerConsidérée normale Pas Surcharges déclenché 54- FR 55- FR D26700 Get it fixed, at your home or ours