Craftsman 919.72427 Specification Chart, Safety Guidelines Definitions, Model No 919-724270

Page 3

SPECIFICATION CHART

Model No.

919-724270

Max. Developed HP

7

Bore

2.375

Stroke-High Pressure

.54"

Low Pressure

1.45"

Voltage-Single Phase

240

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity - Gallons

60

Approximate Cut-in Pressure

145

Approximate Cut-out Pressure

175

SCFM@ 40 psig

9.6

SCFM@ 90 psig

9.0

SAFETY GUIDELINES - DEFINITIONS

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates an

 

 

 

 

 

 

 

Indicates a potentially

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

imminently hazardous

 

 

 

 

 

 

 

hazardous situation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

situation which, if not avoided, will

 

 

which, if not avoided, may result in

 

 

result in death or serious injury.

 

 

minor or moderate injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates a potentially

 

 

 

 

 

 

 

 

Used without the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hazardous situation

 

 

 

 

 

 

 

 

safety alert symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which, if not avoided, could result in

 

 

 

indicates a potentially hazardous

 

 

death or serious injury.

 

 

 

situation which, if not avoided, may

 

 

 

 

 

 

 

 

 

 

 

result in property damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to

cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:

lead from lead-based paints

crystalline silica from bricks and cement and other masonry products

arsenic and chromium from chemically-treated lumber

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools.

When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.

3- ENG

D24450

Image 3
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorTable of Contents Model No 919-724270 Specification ChartSafety Guidelines Definitions Important Safety InstructionsRisk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk of Burns Risk from Moving PartsRisk of Falling Risk of Unsafe Operation Duty Cycle AccessoriesAccessories GlossaryInstallation AssemblyRisk of Electrical Wiring InstructionsVoltage and Circuit Protection Air Distribution SystemTypical Compressed AIR Distribution System Drain Valve OperationKnow Your Air Compressor Description of OperationPressure Release Valve How to StopBefore Starting Check ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesMotor Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves Inspect Air Lines and Fittings for LeaksScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Nut Outlet Tube Pressure Relief Check ValveStorage Problem Cause Correction TroubleshootingProblem Cause Correction Check wiring connection Sears Canada, Inc., Toronto, Ont. M5B 2B8 Table DES MatièresTableau DES Spécifications Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Risque Risque D’EXPLOSION OU D’INCENDIERisque DE Projection D’OBJETS Risque D’ÉCLATEMENTRisque PAR Inhalation Risque DE Choc ÉlectriqueRisque DE Brûlures Risque Relié AUX Pièces MobilesRisque DE Chute Risque Dune Utilisation Dangereuse Lexique AccessoiresCycle DE Service AccessoiresAssemblage Système de distribution dair Directives de câblageDirectives DE Mise À LA Terre Tension et protection des circuitsSystème DE Distribution Dair Typique Utilisation Familiarisez-vous avec votre compresseur dairDescription du fonctionnement Procédures de rodage Utilisation de lappareilAvant le démarrage Arrêt de lappareilMise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéFiltre à air Inspection et remplacement MoteurFiltre à air Entretien ET Réglages Remplacement ou nettoyage de la soupape de retenueRangement Peut éclater ou exploser DépannageProblème Cause Correction SerrerCognements Pas Surcharges déclenché Remarque ENG D24450 Get it fixed, at your home or ours