Xantrex Technology HF 1000, HF 1800 manual To adjust the alarm setting

Page 32

To adjust the alarm setting:

By default the alarm is set to ON.

Press and hold the Select button for two seconds.

The display shows “AL0” indicating that the alarm is OFF. The display shows “AL1” indicating that the alarm is ON.

Whenever the alarm setting is changed, the display will temporarily show either “AL0” or “AL1” and after a few seconds will return to displaying what was on the screen prior to the adjustment.

Note: The alarm setting will reset to its default setting when the Freedom HF’s inverter button is turned OFF then turned ON again.

To adjust the charging current:

By default the charging current is set to:

20A for the Freedom HF 1000

40A for the Freedom HF 1800

1.Press and hold the Inverter button for five seconds. The unit will go into Charge Current Setting Mode.

2.Press the Select button to toggle between the different Amp ratings.

2 5 10 20 for the Freedom HF 1000

2 1020 40 for the Freedom HF 1800

3.Choose the desired charging current by stopping at the value shown on the display. To maximize unit performance, see Table 3-1 “Charging Current Guidelines” below.

Wait for five seconds and the charging current is set.

After the charging current is set, the display will return to displaying what was on the screen prior to the adjustment.

3–4

975-0390-01-01

Image 32
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision About This Guide PurposeScope AudienceConventions Used Related InformationImportant Safety Instructions Safety Personal Precautions When Working With Batteries Marine Unit Location Precautions for Using Rechargeable Appliances Page Contents Troubleshooting SpecificationsFigures Xiv Tables Xvi Introduction Freedom HF Inverter/Charger Independent Power System ShutdownPage Features Materials List Freedom HF Inverter/Charger unitDefault Settings for the Freedom HF System Front PanelSide Panel Rear PanelDisplay Panel FreedomPage Configuration Setting Battery Types on the Main Unit To adjust the battery type settingAdjusting Display, Alarm, and Charging Current Settings To adjust what is being displayed on the screenTo adjust the alarm setting 1Charging Current Guidelines Page Operation Display Panel Operation Inverter buttonOperating in Shore Power Mode Operating in Inverter Mode Turning the Inverter Function On and OffStatus LED During Inverter Mode Checking Battery StatusOperating Several Loads at Once Checking Output PowerTurning the Audible Alarm on or OFF Transitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerInput Voltage Power OutputOperating Limits High Surge Loads Inverter LoadsOverload Conditions Over-temperature Conditions Trouble LoadsBattery Charging 1Three-stage Charging ProcessFUL Routine Maintenance BatteriesPage Troubleshooting HF Inverter/Charger during operationGeneral Troubleshooting Guidelines General Troubleshooting Guidelines Television Reception Common ProblemsBuzz in Audio Equipment E01 E08 To reset error codes E10 to E12 Troubleshooting Reference 2Troubleshooting ReferenceTroubleshooting Reference Inverter Applications Resistive LoadsMotor Loads Long Transfer TimesPage Specifications Electrical Specifications Inverter Mode Freedom HFElectrical Specifications Charge Mode Environmental Specifications System SpecificationsPhysical Specifications Regulatory ApprovalsInverter Overload Operation Invert Power Derating vs. Ambient Temperature Charger Output Current vs. AC Input Voltage Table A-1Charging VoltagePage Warranty and Return Information WarrantyWA-2 Return Material Authorization Policy DisclaimerProduct ExclusionsReturn Procedure Out of Warranty ServiceInformation About Your System 806-1840WA-6 Index 975-0390-01-01 IX-1IX-2 Page Xantrex Technology Inc