Xantrex Technology HF 1800, HF 1000 manual Electrical Specifications Charge Mode

Page 63

Electrical Specifications: Charge Mode

Electrical Specifications: Charge Mode

AC Input

Freedom HF 1000

Freedom HF 1800

 

 

 

Operating voltage range

90–130 Vac

90–130 Vac

 

 

 

Nominal current

5Aac at 20A charge,

10Aac at 40A

 

120 Vac in

charge, 120 Vac in

 

 

 

Nominal frequency

60 Hz

60 Hz

DC Output

Freedom HF 1000

Freedom HF 1800

 

 

 

Nominal voltage

12.0 Vdc

12.0 Vdc

 

 

 

Min battery voltage for charging

0.0 Vdc

0.0 Vdc

 

 

 

Max output voltage

14.4 Vdc

14.4 Vdc

 

 

 

Nominal output current

User selectable:

User selectable:

 

2A, 5A, 10A, 20A

2A, 10A, 20A, 40A

 

 

Charger current derating

Automatically reduce charger current as

 

internal temperature exceeds 80 °C, and

 

input Vac approaches low transfer.

 

 

 

Efficiency at nominal output

≥75%

≥75%

Other

Freedom HF 1000

Freedom HF 1800

 

 

Battery type settings

Flooded (default), Gel, AGM, or

 

Fixed (13.5V)

 

 

 

Charge algorithms

Three stages (Bulk, Absorption, and Float)

 

 

 

Independent battery banks

1

1

 

 

 

975-0390-01-01

A–3

Image 63
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision Audience About This GuidePurpose ScopeRelated Information Conventions UsedImportant Safety Instructions Safety Personal Precautions When Working With Batteries Marine Unit Location Precautions for Using Rechargeable Appliances Page Contents Specifications TroubleshootingFigures Xiv Tables Xvi Introduction Freedom HF Inverter/Charger Shutdown Independent Power SystemPage Features Freedom HF Inverter/Charger unit Materials ListFront Panel Default Settings for the Freedom HF SystemRear Panel Side PanelFreedom Display PanelPage Configuration To adjust the battery type setting Setting Battery Types on the Main UnitTo adjust what is being displayed on the screen Adjusting Display, Alarm, and Charging Current SettingsTo adjust the alarm setting 1Charging Current Guidelines Page Operation Inverter button Display Panel OperationOperating in Shore Power Mode Turning the Inverter Function On and Off Operating in Inverter ModeChecking Battery Status Status LED During Inverter ModeChecking Output Power Turning the Audible Alarm on or OFFOperating Several Loads at Once Transitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModePower Output Operating LimitsInput Voltage Inverter Loads Overload ConditionsHigh Surge Loads Trouble Loads Over-temperature Conditions1Three-stage Charging Process Battery ChargingFUL Batteries Routine MaintenancePage HF Inverter/Charger during operation TroubleshootingGeneral Troubleshooting Guidelines General Troubleshooting Guidelines Common Problems Buzz in Audio EquipmentTelevision Reception E01 E08 To reset error codes E10 to E12 2Troubleshooting Reference Troubleshooting ReferenceTroubleshooting Reference Resistive Loads Inverter ApplicationsLong Transfer Times Motor LoadsPage Specifications Freedom HF Electrical Specifications Inverter ModeElectrical Specifications Charge Mode Regulatory Approvals Environmental SpecificationsSystem Specifications Physical SpecificationsInverter Overload Operation Invert Power Derating vs. Ambient Temperature Table A-1Charging Voltage Charger Output Current vs. AC Input VoltagePage Warranty Warranty and Return InformationWA-2 Exclusions Return Material Authorization PolicyDisclaimer ProductOut of Warranty Service Return Procedure806-1840 Information About Your SystemWA-6 975-0390-01-01 IX-1 IndexIX-2 Page Xantrex Technology Inc