Xantrex Technology HF 1800, HF 1000 manual Operating in Shore Power Mode

Page 37

Operating in Shore Power Mode

Operating in Shore Power Mode

The Freedom HF operates in shore power mode when an AC source (a generator or utility power) is present at the AC input terminals. When the AC source is within operating range, the Freedom HF unit bypasses inverter function and powers the appliances connected to the unit. See “Transitioning from Inverter Mode to Shore Power” on page 4–7.

The Freedom HF also automatically charges the battery bank that is connected while in shore power mode. See “Battery Charging” on page 4–11.

The Green status LED lights up to indicate that the Freedom HF is using utility (or generator) power and the battery is full. A flashing Green LED indicates that the unit is charging the battery.

When shore power is present, AC power will automatically pass through the Freedom HF. Pressing the Inverter button on the display panel will not interrupt the supply of shore power. Shore Power mode supersedes Inverter mode.

When the Freedom HF ‘s Inverter button is turned ON and the AC source is outside the operating range or is disconnected, the transfer switch automatically switches to inverter mode. See “Transitioning from Shore Power to Inverter Mode” on page 4–7.

975-0390-01-01

4–3

Image 37
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision Purpose About This GuideScope AudienceRelated Information Conventions UsedImportant Safety Instructions Safety Personal Precautions When Working With Batteries Marine Unit Location Precautions for Using Rechargeable Appliances Page Contents Specifications TroubleshootingFigures Xiv Tables Xvi Introduction Freedom HF Inverter/Charger Shutdown Independent Power SystemPage Features Freedom HF Inverter/Charger unit Materials ListFront Panel Default Settings for the Freedom HF SystemRear Panel Side PanelFreedom Display PanelPage Configuration To adjust the battery type setting Setting Battery Types on the Main UnitTo adjust what is being displayed on the screen Adjusting Display, Alarm, and Charging Current SettingsTo adjust the alarm setting 1Charging Current Guidelines Page Operation Inverter button Display Panel OperationOperating in Shore Power Mode Turning the Inverter Function On and Off Operating in Inverter ModeChecking Battery Status Status LED During Inverter ModeTurning the Audible Alarm on or OFF Checking Output PowerOperating Several Loads at Once Transitioning from Inverter Mode to Shore Power Transitioning from Shore Power to Inverter ModeOperating Limits Power OutputInput Voltage Overload Conditions Inverter LoadsHigh Surge Loads Trouble Loads Over-temperature Conditions1Three-stage Charging Process Battery ChargingFUL Batteries Routine MaintenancePage HF Inverter/Charger during operation TroubleshootingGeneral Troubleshooting Guidelines General Troubleshooting Guidelines Buzz in Audio Equipment Common ProblemsTelevision Reception E01 E08 To reset error codes E10 to E12 2Troubleshooting Reference Troubleshooting ReferenceTroubleshooting Reference Resistive Loads Inverter ApplicationsLong Transfer Times Motor LoadsPage Specifications Freedom HF Electrical Specifications Inverter ModeElectrical Specifications Charge Mode System Specifications Environmental SpecificationsPhysical Specifications Regulatory ApprovalsInverter Overload Operation Invert Power Derating vs. Ambient Temperature Table A-1Charging Voltage Charger Output Current vs. AC Input VoltagePage Warranty Warranty and Return InformationWA-2 Disclaimer Return Material Authorization PolicyProduct ExclusionsOut of Warranty Service Return Procedure806-1840 Information About Your SystemWA-6 975-0390-01-01 IX-1 IndexIX-2 Page Xantrex Technology Inc