Xantrex Technology HF 1000, HF 1800 manual Electrical Specifications Inverter Mode, Freedom HF

Page 62

Electrical Specifications: Inverter Mode

DC Input

Freedom HF 1000

Freedom HF 1800

 

 

 

Operating voltage range

10.5V–15.5V

10.5V–15.5V

 

 

 

Safe non-operating voltage range

0–16 Vdc

0–16 Vdc

 

 

 

Normal voltage

12.5V

12.5V

 

 

 

Nominal current at full load

100A

180A

AC Output

Freedom HF 1000

Freedom HF 1800

 

 

 

Output voltage

115 Vac

115 Vac

 

 

 

Continuous power

1.0kW @ 25 °C

1.8kW @ 25 °C

 

 

 

Surge power

17A

30A

 

(2kW for 200 ms)

(3.6kW for 300 ms)

 

 

 

Max short-circuit current

55A peak

55A peak

 

 

 

Frequency

60 Hz

60 Hz

 

 

 

Wave shape

Modified Sinewave

Modified Sinewave

 

 

Power derating above 40 °C ambient

See “Invert Power Derating vs. Ambient

temp

Temperature” on page A–6.

 

 

 

Peak efficiency

≥87%

≥87%

 

 

 

Full load efficiency

≥80%

≥80%

Other

Freedom HF 1000

Freedom HF 1800

 

 

 

No load input power (producing

≤10W

≤10W

output voltage)

 

 

 

 

 

Off mode current draw

≤1mA

≤1mA

A–2

975-0390-01-01

Image 62
Contents Freedom HF Page Freedom HF Inverter/Charger Date and Revision Scope About This GuidePurpose AudienceConventions Used Related InformationImportant Safety Instructions Safety Personal Precautions When Working With Batteries Marine Unit Location Precautions for Using Rechargeable Appliances Page Contents Troubleshooting SpecificationsFigures Xiv Tables Xvi Introduction Freedom HF Inverter/Charger Independent Power System ShutdownPage Features Materials List Freedom HF Inverter/Charger unitDefault Settings for the Freedom HF System Front PanelSide Panel Rear PanelDisplay Panel FreedomPage Configuration Setting Battery Types on the Main Unit To adjust the battery type settingAdjusting Display, Alarm, and Charging Current Settings To adjust what is being displayed on the screenTo adjust the alarm setting 1Charging Current Guidelines Page Operation Display Panel Operation Inverter buttonOperating in Shore Power Mode Operating in Inverter Mode Turning the Inverter Function On and OffStatus LED During Inverter Mode Checking Battery StatusOperating Several Loads at Once Checking Output PowerTurning the Audible Alarm on or OFF Transitioning from Shore Power to Inverter Mode Transitioning from Inverter Mode to Shore PowerInput Voltage Power OutputOperating Limits High Surge Loads Inverter LoadsOverload Conditions Over-temperature Conditions Trouble LoadsBattery Charging 1Three-stage Charging ProcessFUL Routine Maintenance BatteriesPage Troubleshooting HF Inverter/Charger during operationGeneral Troubleshooting Guidelines General Troubleshooting Guidelines Television Reception Common ProblemsBuzz in Audio Equipment E01 E08 To reset error codes E10 to E12 Troubleshooting Reference 2Troubleshooting ReferenceTroubleshooting Reference Inverter Applications Resistive LoadsMotor Loads Long Transfer TimesPage Specifications Electrical Specifications Inverter Mode Freedom HFElectrical Specifications Charge Mode Physical Specifications Environmental SpecificationsSystem Specifications Regulatory ApprovalsInverter Overload Operation Invert Power Derating vs. Ambient Temperature Charger Output Current vs. AC Input Voltage Table A-1Charging VoltagePage Warranty and Return Information WarrantyWA-2 Product Return Material Authorization PolicyDisclaimer ExclusionsReturn Procedure Out of Warranty ServiceInformation About Your System 806-1840WA-6 Index 975-0390-01-01 IX-1IX-2 Page Xantrex Technology Inc