3.6.6Connection to Auxiliary Contact

On these three terminals is a potential free change-over contact. The maximal permitted current and voltage for this is 16A/250Vac. The LED 5 “Contact active” shows the position of them: alight means active and off means non-active. The schematic view of the connections on the front shows the relay in the non-active mode.

3.5.7 Connection to Remote control

The Remote Control RCC 01 is connected in the terminal marked „Remote control“ with a RJ11/8 connector. The Remote Control can be plugged IN or plugged OUT during any operation situation. Push in the connector, without forcing it, until you hear the „click“, now the connector is locked in place. The same applies to the plug in the Remote Control. The length of the cable for Remote Control should not exceed 40m. We deliver it with 20m cable.

3.6.7Connection to Temperature Sensor (Temp.)

The Temperature sensor CT-35 is connected in the terminal marked „Temp“ with a RJ11/6 connec- tor. The Temperature Sensor can be plugged IN or plugged OUT during any operating situation. Push in the connector without forcing it, until you hear a „click“, now the connector is locked in place. The Temperature Sensor must be glued to the wall of the battery or close to it. The Tem- perature Sensor cable must not be tied together with the battery cables or laid in a rope/bundle.

4 Control

4.1Display and control parameters

AC IN

CHARGER Current adj.

Reset

Solar charge

Equalize

1

22

3

14

7 23

0% 100% 0 20W

19ON /

OFF

BATTERY

8

24

13

15

12

AC OUT Search mode

INVERTER

Standby adj.

Off / Alarm Temporary off

Batt 100%

Absorption

Batt undervolt. Batt overvolt.

User manual

XP-COMPACT V2.0 E

10

Image 11
Contents XP-COMPACT V2.0 E XP-COMPACT XPCIntroduction Mounting and installingSummary General InformationMaintenance EC Compliance Technical Data Operating instructions Quality and WarrantyWarranty Disclaimer General InformationSpecial Precautions PrecautionsDescription of main functions Principle schematicIntroduction Connection in parallel Battery connectionsRemote control Solar charge controller optionalProtection cover IP23 Mounting and installingInstallation place FixingSolar + Connecting panel / Front sideProtection cover for the terminals con- nections Connecting the 230Vac-Consumer Appliance AC Output Cabling/wiringPre-installation settings Connection to batteryDisplay and control parameters Connection to Remote controlConnection to Temperature Sensor Temp ControlMarking LED lit LED blinks Light Emitting Diodes LEDInverter Push buttonsTurning Knobs Cycle of charge Battery chargerBattery Condition Charging current Transfer systemEqualization charging Set the transfer voltage threshold Fast UPS- Mode for the Transfer SwitchDelayed mode of the Transfer System Solar charge controller optionPower monitor Remote ControlTemperature sensor Remote control plug-inProgramming Battery ConditionFault indicator Remote alarm contact and on/off controlBattery voltages and absorption time Standard settingReset value Example Program the auxiliary contactPrinciple Disabling some of the XP-COMPACT functions MaintenanceDiagram of the different mode EC ComplianceModel Technical Data