BATTERIES
Beware of so-called maintenance-free
batteries. These batteries have calcium alloyed with the lead and hold the liquid electrolyte in a
Gel Cell Batteries
Gel cell batteries are
•No Maintenance
•Low
•Low Internal Resistance
Even though gel cells are sealed batteries, the battery compartment should still be ventilated.
Advanced AGM (Absorbed Glass Mat) Batteries
This battery is lead acid but maintenance- free. The performance is similar to gel cell batteries. The charge parameters are similar to wet cell batteries.
Battery Selection
The most important feature to consider in making your battery selection is to select true deep cycle batteries rated in
BATTERY INTERCONNECTION
In most cases, you will be using a bank of two or more batteries with your inverter/ charger. You may connect batteries together in two configurations, series and parallel depending on their voltage.
12
Series
Connecting two batteries in series will double the voltage of the battery bank. For instance, two 6 volt batteries connected in series will produce 12 volts. The
+
+
+
Series
Series Increase Voltage
+ | + | + |
6V | 6V | 12V INVERTER |
_ | _ | _ |
|
| |
EACH BATTERY |
| TOTAL BATTERY |
CAPACITY: |
| BANK CAPACITY: |
220 |
| 220 |
| ||
@ 6 VDC |
| @ 12 VDC |