Thomas & Betts 15D, 20D owner manual Glossary

Page 33

GLOSSARY

Alternating Current (AC) An electric current that reverses direction at regular intervals. Sources of alternating current are shore power, generator power, inverter power or household current.

Ampere (Amp, A) The unit of measure of electron flow rate of current through a circuit.

Ampere-hour(Amp-Hr., AH) A unit of measure for a battery’s electrical storage capacity, obtained by multiplying the current in amperes by the time in hours of discharge (Example: a battery which delivers 5 amperes for 20 hours delivers 5 amperes times 20 hours, or 100 Amp-Hr. of capacity.)

Ampere-Hour Capacity The ability of a fully charged battery to deliver a specified quantity of electricity (Amp-Hr., AH) at a given rate (Amp, A) over a definite period of time (Hr.). The capacity of a battery depends upon a number of factors such as: active material, weight, density, adhesion to grid, number, design and dimensions of plates, plate spacing design of separators, specific gravity and quantity of available electrolyte, grid alloys, final limiting voltage, discharge rate, temperature, internal and external resistance, age and life of the battery (bank).

AGM (Absorbed Glass Mat) Battery A lead acid, maintenance-free battery.

AWG (American Wire Gauge) A standard used to measure the size of wire.

Circuit An electric circuit is the path of an electric current. A closed circuit has a complete path. An open circuit has a broken or disconnected path.

Circuit (Series) A circuit which has only one path for the current to flow. Batteries arranged in series are connected with the negative of the

first to the positive of the second, negative of the second to the positive of the third, etc. If two 6 Volt batteries of 50 ampere-hours capacity are connected in series, the circuit voltage is equal to the sum of the two battery voltages, or 12 Volts, and the ampere-hour capacity of the combination is 50 ampere-hours.

Circuit (Parallel) A circuit which provides more than one path for current flow. A parallel arrangement of batteries (of like voltage and capacity) would have all positive terminals connected to a conductor and all negative terminals connected to another conductor. If two 12 Volt batteries of 50 ampere-hour capacity each are connected in parallel, the circuit voltage is 12 Volts, and the ampere-hour capacity of the combination is 100 ampere-hours.

Combi Freedom CombiTM is a trademark of Heart Interface to indicate a combination inverter/charger.

Current The rate of flow of electricity or the movement rate of electrons along a conductor. It is comparable to the flow of a stream of water. The unit of measure for current is ampere.

Cycle In a battery, one discharge plus one recharge equals one cycle.

Direct Current (DC) Current that flows continuously in one direction such as that from batteries, photovoltaics, alternators, chargers and DC generators.

33

Part No. 90-0123-00 Libertycombi.p65 10/26/98

Image 33
Contents INVERTER/CHARGER Safety Summary Table of Contents Freedom 15 & 15D Watts Freedom 20 & 20D IntroductionFreedom 15 & 15D Amps DC Freedom 20 & 20D Electronic Protection15D 20D Things YOU should KnowTemperature Sensitive Charging Front Panel Controls and Indicators External AC PowerInvert Mode Charge ModeLOW Battery Red LED Battery Type SelectionStatus LEDs Operation StatusLOW Battery & OVERTEMP/OVERLOAD TSC Temperature Sensitive ChargingOptional Remotes Advanced Remote Control Panels Link Instrument Remote Control PanelLink Link 2000RBattery Types Wet Cell BatteriesQuality deep-cycle batteries offer good Batteries Battery InterconnectionBattery Bank Ratings and Sizing ParallelOnly similar batteries should be AMP-HOUR Consumption Formulas Typical Power ConsumptlonBattery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charging Battery Charger Voltage Settings Unvented compartments containing Installation PrecautionsConfirm that your shipping carton contains Typical Tools NeededInstallation Auxiliary Switch Port Jumper Neutral Bonding GroundingAC Wiring InstallationDC Wiring Ground Fault Circult InterruptersPathMaker Models Recommended Fuse UL Listed Class T Battery Cable FusingTest the transfer function InstallationTest the battery charger function Troubleshooting LED Status Troubleshooting Glossary LED Light Emitting Diode Indicator light Specifications Phone numbers 253 Warranty