INSTALLATION

Remove the positive (+) battery cable terminal cover from the unit and attach the battery cable. Tighten the battery terminal bolts to a torque value between 160 inch-pounds and 180 inch-pounds. Replace the cover for the positive terminal.

The negative (-) cable should be connected directly to the negative post of the house or auxiliary battery bank or the ground side of a current shunt. Tighten securely.

The positive (+) battery cable must be fused and connected to the positive post of the house or auxiliary battery bank, or through a selector switch to one or more battery banks.

A spark may be generated when the final battery connection is made. This is normal; do not be alarmed. However, do not make the final connection in the presence of flammable fumes.

If multiple batteries are used, the interconnecting jumper cables must be the same AWG or larger as those connected to the inverter/charger.

If multiple battery banks are to be charged, a battery bank selector switch can be installed, allowing the banks to be charged either individually or simultaneously. A solenoid can also be used. The PathMaker Battery Combiner, by Heart Interface, may be used to connect multiple battery banks. The PathMaker battery combiner is available from your Heart dealer.

NOTE: If installing in a vehicle, do not use the vehicle frame as the negative conductor.

POSITIVE (+)

(Battery Cable

Cover on)

NEGATIVE (-)

(Battery Cable

Cover on)

PathMaker 100, 2 Channel

PathMaker Models

70 Amp, 2 Channel

100 Amp, 2 Channel

100 Amp, 3 Channel

200 Amp, 2 Channel

200 Amp, 3 Channel

Freedom 15D

27

Part No. 90-0123-00 Libertycombi.p65 10/26/98

Image 27
Contents INVERTER/CHARGER Safety Summary Table of Contents Electronic Protection IntroductionFreedom 15 & 15D Watts Freedom 20 & 20D Freedom 15 & 15D Amps DC Freedom 20 & 20D15D 20D Things YOU should KnowTemperature Sensitive Charging Charge Mode External AC PowerFront Panel Controls and Indicators Invert ModeOperation Status Battery Type SelectionLOW Battery Red LED Status LEDsLOW Battery & OVERTEMP/OVERLOAD TSC Temperature Sensitive ChargingOptional Remotes Link 2000R Remote Control PanelAdvanced Remote Control Panels Link Instrument LinkBattery Types Wet Cell BatteriesQuality deep-cycle batteries offer good Batteries Battery InterconnectionBattery Bank Ratings and Sizing ParallelOnly similar batteries should be AMP-HOUR Consumption Formulas Typical Power ConsumptlonBattery Charging Battery ChargingFreedom Battery Chargers Battery charger stages are Acceptance to Float Transition Points Battery Charging Battery Charging Battery Charger Voltage Settings Typical Tools Needed Installation PrecautionsUnvented compartments containing Confirm that your shipping carton containsInstallation Auxiliary Switch Port Jumper Neutral Bonding GroundingAC Wiring InstallationDC Wiring Ground Fault Circult InterruptersPathMaker Models Recommended Fuse UL Listed Class T Battery Cable FusingTest the transfer function InstallationTest the battery charger function Troubleshooting LED Status Troubleshooting Glossary LED Light Emitting Diode Indicator light Specifications Phone numbers 253 Warranty