Liebert gxt2u user manual Preparation, Tower UPS Installation

Page 12

Installation

4.0INSTALLATION

4.1PREPARATION

1.Visually inspect the UPS for freight damage. Report damage to the carrier and your local dealer or Liebert representative.

CAUTION

! The UPS is heavy (see 11.0 - Specifications). Take proper precautions when lifting or moving it.

2. Decide where to place the Liebert GXT2U. Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives, and conductive contaminants. Maintain a minimum clearance of 4 in. (100mm) in the front and rear of the UPS. Maintain an ambient temperature range of 32°F to 104°F (0°C to 40°C).

NOTE

UPS operation in temperatures above 77°F (25°C) reduces battery life.

3.The Liebert GXT2U may be installed in either a tower configuration or in a rack, depending on available space and use considerations. Determine the type of installation and follow the appropriate instructions in either 4.2 - Tower UPS Installation or 4.3 - Rack-Mount UPS Conversion and Installation.

4.2TOWER UPS INSTALLATION

When using the Liebert GXT2U in a tower configuration, use the included support base (shown below, left) to stabilize the UPS.

If any battery cabinets are added, they will include spacers to accom- modate the additional cabinets (shown below, right).

Support base

Spacers added to support

 

base to accommodate

 

additional battery cabinets

8

DISCONTINUED

 

PRODUCT

Image 12
Contents Liebert GXT2U DIS Product Table of Contents Tables Important Safety Instructions Product Glossary of Symbols Introduction RECTIFIER/POWER Factor Correction PFC Circuit Major ComponentsTransient Voltage Surge Suppression Tvss EMI/RFI Filters InverterBattery Charger BatteryDC to DC Converter Dynamic BypassLiebert GXT2U, Rear View Installation Tower UPS InstallationPreparation RACK-MOUNT UPS Conversion and Installation Bracket assembly into rack Prepare the UPS or battery Cabinet the equipment for UPS External Battery Cabinet Installation UPSControls and Indicators ON/ALARM SILENCE/MANUAL Battery Test ButtonLOAD/BATTERY Level Indicators 4 GREEN, 1 Amber Fault Indicator LED REDBypass Indicator LED Amber Battery Indicator LED AmberAC Input Indicator LED Green Output Voltage SelectionNormal Mode Operation Bypass Mode OperationOperating Instructions Battery Mode Operation Battery Recharge ModeCommunications Communications Interface PortPins 4 & 5 Remote Shutdown on Battery Auto-Enable Output Pin 6 Logic Pins 5 & 6 ANY-MODE ShutdownUPS Intelligent Communications Configuration Program Liebert GXT2U Configuration Program AbilitiesMaintenance Battery ReplacementInternal Battery Replacement Procedures Fuse Replacement Troubleshooting AC LEDTroubleshooting guide Check load equipment for Your UPS has received a Alarm conditions Specifications Model RatingGXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 Battery Cabinet Specifications Battery ParametersBattery RUN Times Product Warranty Registration DIS Product DIS Product DIS Product Disconti Nued Product