Liebert gxt2u user manual Battery Cabinet Specifications, Battery Parameters

Page 38

Battery Cabinet Specifications

12.0BATTERY CABINET SPECIFICATIONS

Model Number

GXT2-48VBATT

GXT2-72VBATT

 

 

 

 

GXT2-500RT120

 

Used With

GXT2-700RT120

 

GXT2-1000RT120

GXT2-3000RT120

UPS Model

GXT2-1500RT120

 

 

 

 

GXT2-2000RT120

 

 

 

 

DIMENSIONS - in. (mm)

 

 

 

 

Unit

3.5 x 21.5 x 17

3.5 x 24.2 x 17

W x D x H

(87 x 547 x 430)

(87 x 618 x 430)

Shipping

10.5 x 27.2 x 23

10.5 x 27.2 x 23

W x D x H

(268 x 692 x 585)

(268 x 692 x 585)

WEIGHT - lb. (kg)

 

 

 

 

 

Unit

65.0 (29.5)

93.6 (42.5)

 

 

 

Shipping

71.1 (32.3)

102.5 (46.5)

 

 

 

BATTERY PARAMETERS

 

 

 

 

Type

Valve-regulated, nonspillable, lead acid

 

 

 

Qty x V x Rating

2 x 4 x 12V x 7.0 or 7.2 AH

2 x 6 x 12V x 9.0 AH

 

 

 

Battery Mfg / Part #

China Storage Battery /

Panasonic / UP-VW1245P1

CSB 1270 F2

Yuasa / REW 45-12

 

Backup Time

See 13.0 - Battery Run Times

 

 

 

ENVIRONMENTAL

 

 

 

 

 

Operating Temp

+32°F to +104°F (0°C to +40°C)

 

 

Storage Temp

+5°F to +122°F (-15°C to +50°C)

 

 

Relative Humidity

0% to 95%, non-condensing

 

 

Operating Elevation

Up to 10,000 ft. (3000m) at 104°F (40°C) without derating

 

 

Storage Elevation

50,000 ft. (15,000 m) maximum

 

 

 

AGENCY

 

 

 

 

 

Safety

UL 1778, c-UL Listed

 

 

RFI/EMI

FCC Part 15, Subpart B, Class A

 

 

Transportation

ISTA Procedure 1A

 

 

 

34

DISCONTINUED

 

PRODUCT

Image 38
Contents Liebert GXT2U DIS Product Table of Contents Tables Important Safety Instructions Product Glossary of Symbols Introduction Transient Voltage Surge Suppression Tvss EMI/RFI Filters RECTIFIER/POWER Factor Correction PFC CircuitMajor Components InverterDC to DC Converter Battery ChargerBattery Dynamic BypassLiebert GXT2U, Rear View Preparation InstallationTower UPS Installation RACK-MOUNT UPS Conversion and Installation Bracket assembly into rack Prepare the UPS or battery Cabinet the equipment for UPS External Battery Cabinet Installation UPSControls and Indicators ON/ALARM SILENCE/MANUAL Battery Test ButtonBypass Indicator LED Amber LOAD/BATTERY Level Indicators 4 GREEN, 1 AmberFault Indicator LED RED Battery Indicator LED AmberAC Input Indicator LED Green Output Voltage SelectionOperating Instructions Normal Mode OperationBypass Mode Operation Battery Mode Operation Battery Recharge ModeCommunications Communications Interface PortPins 4 & 5 Remote Shutdown on Battery Auto-Enable Output Pin 6 Logic Pins 5 & 6 ANY-MODE ShutdownUPS Intelligent Communications Configuration Program Liebert GXT2U Configuration Program AbilitiesMaintenance Battery ReplacementInternal Battery Replacement Procedures Fuse Replacement Troubleshooting AC LEDTroubleshooting guide Check load equipment for Your UPS has received a Alarm conditions Specifications Model RatingGXT2-1500RT120 GXT2-2000RT120 GXT2-3000RT120 Battery Cabinet Specifications Battery ParametersBattery RUN Times Product Warranty Registration DIS Product DIS Product DIS Product Disconti Nued Product