Lux Products TX9600TS operating instructions Hardware Setup Options

Page 17

HARDWARE SETUP OPTIONS:

On the thermostat’s circuit board, there is a row of DIP switches, labeled #1 through #8. The position of these switches will change how the thermostat operates, and also how information is conveyed to you on the LCD display screen. If you make any changes to these options, the changes are not recognized unless you either: change the position of the HEAT/OFF/COOL mode switch, or press the “HW RST” (Hardware Reset) button on the circuit board. The use of this button is further

described in the “ADVANCED FEATURES”

 

 

 

8

section of this manual.

 

 

7

These option switches are very small and should be moved carefully using objects such as: eyeglass screwdriver, fine-point pen, toothpick, or similar. The listing below describes the available choices for each option switch:

 

 

 

6

 

 

 

 

 

 

5

 

 

 

4

 

 

 

3

ON

 

 

2

 

 

 

1

SWITCH #1 (SYSTEM): [OFF/RIGHT = FURN, default] This setting is used for the majority of all heating systems that are not heat pumps. Examples for this setting would be: natural gas furnace, hot water baseboard heat, and oil heat. [ON/LEFT = HP] Use this setting if you have a heat pump unit (which looks just like an outside air conditioning unit, but is used for both cooing and heating).

SWITCH #2 (TYPE): [OFF/RIGHT = PROG, default] The thermostat controls the room temperature by following temperature program periods that you set up based upon your daily routine. [ON/LEFT = MAN] The thermostat operates manually just like a mechanical or non-programmable model. This method of operation is very basic and only shows the room temperature and set temperature; there are no temperature programs, days of the week, or clock times.

SWITCH #3 (PERIODS): [OFF/RIGHT = 4, default] The thermostat uses four temperature program periods in both heating and cooling (MORN, DAY, EVE, and NITE). Each period has a separate start time and a set temperature. [ON/LEFT = 2] The thermostat operates in the same manner as above, however there are only two temperature program periods for heating and cooling (DAY and NITE). This may be more convenient if you are typically home during the day, and only need the set temperature to be different while you are sleeping.

17

Image 17
Contents 9 6 0 0 T S Not Compatible with System CompatibilityCompatible with Tools YOU MAY Need FeaturesRemove OLD Thermostat Mounting LocationThermostat TOP View Install Thermostat BaseWiring Base Plate Notice Wiring InformationConnecting the Wires Important, please read all notes before connecting wires Wiring Diagram NotesWiring Diagrams FAN Wire HOT Water Heating only With a 3-WIRE Zone Valve STAGE, Cooling only Stage Heating and 1-STAGE Cooling Conventional NON Heat PumpConventional NON Heat Pump Stage Heating and 1-STAGE CoolingWith TWO Separate 24V Transformers SINGLE-STAGE Heat Pump System With no AUX or Emergency Heat With AUX and Emergency Heat Heat / 1-COOL, Heat Pump SystemDescribed in the Advanced Features Section of this manual Hardware Setup OptionsPage Complete the Install GAS / Elec Slide Switch FAN OperationBattery Front Panel ItemsOperating Instructions Touchscreen Menu ContentsNite DAYEVE Page Temperature Programs Advanced Features Degrees F Page Page Page Page Page RST Battery Replacement Mercury Warning and Recycling Notice Technical Assistance Limited Warranty˚ F