Page 27

will be 5F (3C) degrees lower than the current set temp. For Cool mode, the set temperature used will be 5F (3C) degrees higher than the current set temp.

NOTE: The Setback settings need to be performed in a timely manner, as the thermostat will timeout and automatically exit these adjustment screens after approximately 10 seconds without a button press.

TO START A SETBACK: Press the MENU button, then press the SCROLL button until “TEMPERATURE SETBACK” is shown, then press the OK button. The words “OVERRIDE LEFT” will appear at the top of the screen, along with two digits and the word “HRS”. Use the UP and DOWN buttons to set the duration for how long you would like to maintain a fixed set temperature (from 1 to 12 hours). If you would like to set the duration for longer than 12 hours, keep pressing the UP button. The display will change from “HRS” left to “DAYS” left, with an available duration of 1 to 30 days. Once you have selected your desired Setback duration, press the NEXT button to advance. The display will change from “OVERRIDE LEFT” left to “OVERRIDE TEMPERATURE”. Use the UP and DOWN buttons to select your desired Set Temperature that will be used during the Setback duration. Once complete, press the NEXT button to accept the setting and return to the Normal Run screen.

TO CANCEL A SETBACK: A Setback can be cancelled by either pressing the HOLD button two times, or by moving the mode switch to OFF, pausing briefly, then switching back to the HEAT or COOL position. When in the Normal Run mode, the display should say either “HEAT MODE” or “COOL MODE”.

TEMPERATURE LIMIT STOPS: There are two independent set temperature

limit stops: a maximum heat set temperature, and a minimum cool set temperature. These stops do not prevent a user from performing normal actions like Temperature Override or Hold. The Heat Limit Stop prevents the set temperature from being adjusted higher than the heat limit setting. The Cool Limit Stop prevents the set temperature from being adjusted lower than the cool limit setting. Each of these temperature stops is user adjustable in one-degree increments, and these settings are protected by a selectable 2- digit code to prevent unauthorized tampering. By default, this 2-digit code is “00”, and the temperature stops can be used as-is with this code.

27

Image 27
Contents 9 6 0 0 T S System Compatibility Compatible withNot Compatible with Tools YOU MAY Need FeaturesRemove OLD Thermostat Mounting LocationThermostat TOP View Install Thermostat BaseWiring Information Connecting the WiresWiring Base Plate Notice Important, please read all notes before connecting wires Wiring Diagram NotesWiring Diagrams FAN Wire HOT Water Heating only With a 3-WIRE Zone Valve STAGE, Cooling only Stage Heating and 1-STAGE Cooling Conventional NON Heat PumpConventional NON Heat Pump Stage Heating and 1-STAGE CoolingWith TWO Separate 24V Transformers SINGLE-STAGE Heat Pump System With no AUX or Emergency Heat With AUX and Emergency Heat Heat / 1-COOL, Heat Pump SystemDescribed in the Advanced Features Section of this manual Hardware Setup OptionsPage Front Panel Items GAS / Elec Slide Switch FAN OperationComplete the Install BatteryOperating Instructions Touchscreen Menu ContentsDAY EVENite Page Temperature Programs Advanced Features Degrees F Page Page Page Page Page RST Battery Replacement Mercury Warning and Recycling Notice Technical Assistance Limited Warranty˚ F