Lux Products TX9600TS operating instructions Advanced Features

Page 24

words “COPY PROGRAM” will flash briefly at the top of the screen, followed by “FROM” and “TO”. Under the word “FROM” will be a flashing day of the week. Using the UP and DOWN buttons, select the day that you want to copy from. Press the NEXT button one time. Your copy from day should now be on steady with the day under the word “TO” flashing. Use the UP and DOWN buttons to select the day that you would like to copy to. A single short press of the COPY button will perform the copy, and the day flashing under the word “TO” will have advanced to the next following day. You may continue to perform short single presses of the COPY button to keep copying from the original source day to the remaining days, one after the other. Specific days may be skipped by pressing the UP button, to advance past them while they are flashing under the word “TO”. Press the EXIT button to return to the Normal Run screen.

ADVANCED FEATURES:

TEMPERATURE SWING SETTING, OFFSET SETTING, AND TEMPERATURE CALIBRATION:

NOTE: The Swing setting, Offset setting, and Calibration settings need to be performed in a timely manner, as the thermostat will timeout and automatically exit these adjustment screens after approximately 10 seconds without a button press.

SWING DESCRIPTION: A thermostat works by turning your heating or cooling system on and off whenever the room temperature varies from the desired set-point temperature. The amount of this variation is called the Swing. Generally your system should cycle on about 3 to 6 times per hour. A smaller swing number makes the system cycle more frequently, so the room temperature is more precise and constant. A larger swing number will make the system remain on for a longer duration each time and decreases the number of cycles per hour. There is only one Swing setting, and this determines the cut-in and cut-out points for both the first and second stages (if present), in both Heat mode and Cool mode. The swing setting range is between #1 and #9 (0.25°F to 2.25°F, in 0.25°F degree increments (or 0.14°C to 1.25°C, in 0.14°C degree increments for Celsius)). Swing number 1 is the default setting.

OFFSET DESCRIPTION: This setting is shown as a number of degrees, and is similar in nature to the Swing however this only effects the operation of the second (auxiliary) heating stage, if present. The setting range for Offset is

24

Image 24
Contents 9 6 0 0 T S System Compatibility Compatible withNot Compatible with Features Tools YOU MAY NeedMounting Location Remove OLD ThermostatInstall Thermostat Base Thermostat TOP ViewWiring Information Connecting the WiresWiring Base Plate Notice Wiring Diagram Notes Important, please read all notes before connecting wiresWiring Diagrams FAN Wire HOT Water Heating only With a 3-WIRE Zone Valve STAGE, Cooling only Conventional NON Heat Pump Stage Heating and 1-STAGE CoolingStage Heating and 1-STAGE Cooling Conventional NON Heat PumpWith TWO Separate 24V Transformers SINGLE-STAGE Heat Pump System With no AUX or Emergency Heat Heat / 1-COOL, Heat Pump System With AUX and Emergency HeatHardware Setup Options Described in the Advanced Features Section of this manualPage GAS / Elec Slide Switch FAN Operation Complete the InstallBattery Front Panel ItemsTouchscreen Menu Contents Operating InstructionsDAY EVENite Page Temperature Programs Advanced Features Degrees F Page Page Page Page Page RST Battery Replacement Technical Assistance Limited Warranty Mercury Warning and Recycling Notice˚ F