Lux Products TX9600TS operating instructions

Page 22

LCD DISPLAY BACKLIGHT: The display screen is lighted to assist viewing at nighttime, or in locations with low light levels. A press of any area on the touch panel will light the display for approximately 10 seconds. Any screen presses that occur while the light is on will reset the 10-second timer, causing the screen to remain illuminated for an additional 10 seconds.

TEMPERATURE OVERRIDE: While in the Normal Run screen, the set temperature can be temporarily changed by pressing the Set Temperature digits, then pressing the UP or DOWN buttons. The set temperature will return to the programmed value stored in memory when the start time of the next upcoming program period is reached (Morn, Day, Eve, Nite). While a Temporary Override is in effect, the words “HEAT OVRRIDE” or “COOL OVRRIDE” will be shown in the display screen. An Override may be cancelled by either pressing the HOLD button two times, or by moving the mode switch to OFF, pausing briefly, then switching back to the HEAT or COOL position. When in the Normal Run mode, the display should say either “HEAT MODE” or “COOL MODE”.

MINIMUM RUN TIME: The thermostat has a default internal time delay of 5 minutes between load-on and load-off activations to prevent heating or cooling system damage, which can occur from very frequent cycling. If heating or cooling does not turn on right away with a manual change in set temperature, please wait at least 5 minutes and the system should resume normal operation.

TEMPERATURE HOLD: A Temperature Hold is used for maintaining a fixed set temperature. Once a Hold is initiated, the thermostat will maintain the set temperature indefinitely. A Hold may be used for days, weeks, or even months at a time, as long as the thermostat has adequate power. To enter Hold mode: press the HOLD button one time and the words “HEAT HOLD” or “COOL HOLD” will appear in the display. To cancel a Hold, press the HOLD button one more time. If a mains power failure occurs during a Temperature Hold, the thermostat will continue to remain in Hold mode even after the power comes back on.

NOTE: If you plan to leave the thermostat in Hold mode for an extended duration (unattended), it is advisable to install new Energizer® or DURACELL® "AA" size alkaline batteries prior to leaving to ensure reliable operation of your heating and cooling system.

22

Image 22
Contents 9 6 0 0 T S Compatible with System CompatibilityNot Compatible with Features Tools YOU MAY NeedMounting Location Remove OLD ThermostatInstall Thermostat Base Thermostat TOP ViewConnecting the Wires Wiring InformationWiring Base Plate Notice Wiring Diagram Notes Important, please read all notes before connecting wiresWiring Diagrams FAN Wire HOT Water Heating only With a 3-WIRE Zone Valve STAGE, Cooling only Conventional NON Heat Pump Stage Heating and 1-STAGE CoolingStage Heating and 1-STAGE Cooling Conventional NON Heat PumpWith TWO Separate 24V Transformers SINGLE-STAGE Heat Pump System With no AUX or Emergency Heat Heat / 1-COOL, Heat Pump System With AUX and Emergency HeatHardware Setup Options Described in the Advanced Features Section of this manualPage Battery GAS / Elec Slide Switch FAN OperationComplete the Install Front Panel ItemsTouchscreen Menu Contents Operating InstructionsEVE DAYNite Page Temperature Programs Advanced Features Degrees F Page Page Page Page Page RST Battery Replacement Technical Assistance Limited Warranty Mercury Warning and Recycling Notice˚ F