Lux Products TX9600TS operating instructions Temperature Programs

Page 23

STATIC NOTICE: This thermostat is protected against normal static electric discharges, however to minimize the risk of damaging the unit in extremely dry weather, please touch a grounded metal object before touching your thermostat.

TEMPERATURE PROGRAMS:

By default, this thermostat has 4 separate program periods for both Heat and Cool mode, they are: MORN, DAY, EVE, and NITE. Each period ends at the start time of the following period. The heat programs are set in HEAT mode, and the cool programs are set in COOL mode.

NOTE: If the thermostat is configured to use only 2 periods per day instead of 4 (HARDWARE SETUP OPTIONS), the thermostat will only use the DAY and NITE periods. The MORN and EVE periods will not be visible on the screen.

The following examples are shown using Heat mode. Programming in Cool mode is done in the same exact manner with the System Mode switch in the Cool position.

SET TEMPERATURE PROGRAMS: Press the MENU button, then press the SCROLL button until “SET/REVIEW HEAT PROGMS” is shown, then press the OK button to enter the programming screen. Use the UP and DOWN buttons to adjust the start time for the MORN period, then press the NEXT button to advance. Use the UP and DOWN buttons to adjust the set temperature for the MORN period, then press the NEXT button to advance. Now adjust the start time and set temperature for the DAY period, pressing the NEXT button after each to advance. Continue with these same steps to adjust the start times and set temperatures for the EVE and NITE program periods.

When the NITE period is finished the thermostat will advance to Tuesday, with the MORN period start time flashing. Perform the same steps that you used for setting the Monday periods, pressing the NEXT button to advance through each flashing value.

PROGRAM COPY FEATURE: The Copy feature allows you to copy all of the program information from any one single day, to any other day of the week. To copy heat programs, the thermostat must be in Heat mode, and to copy cool programs, the thermostat must be in Cool mode. Emergency Heat (heat pump configurations only) uses the Heat temperature program. While in a temperature programming screen, press the “COPY” button one time. The

23

Image 23
Contents 9 6 0 0 T S Not Compatible with System CompatibilityCompatible with Tools YOU MAY Need FeaturesRemove OLD Thermostat Mounting LocationThermostat TOP View Install Thermostat BaseWiring Base Plate Notice Wiring InformationConnecting the Wires Important, please read all notes before connecting wires Wiring Diagram NotesWiring Diagrams FAN Wire HOT Water Heating only With a 3-WIRE Zone Valve STAGE, Cooling only Stage Heating and 1-STAGE Cooling Conventional NON Heat PumpConventional NON Heat Pump Stage Heating and 1-STAGE CoolingWith TWO Separate 24V Transformers SINGLE-STAGE Heat Pump System With no AUX or Emergency Heat With AUX and Emergency Heat Heat / 1-COOL, Heat Pump SystemDescribed in the Advanced Features Section of this manual Hardware Setup OptionsPage Front Panel Items GAS / Elec Slide Switch FAN OperationComplete the Install BatteryOperating Instructions Touchscreen Menu ContentsNite DAYEVE Page Temperature Programs Advanced Features Degrees F Page Page Page Page Page RST Battery Replacement Mercury Warning and Recycling Notice Technical Assistance Limited Warranty˚ F