W1751 25"
ELECTRICAL
220V Operation
The Shop Fox Model W1751 has a 7.5 HP, 32A, 220V
We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes.
If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire
Extension Cords
We do not recommend using an extension cord for 220V operation. When it is necessary to use an extension cord, use the following guidelines:
•Use cords rated for Standard Service
•Never exceed a length of 50 feet
•Ensure cord has a ground wire and pin
•Do not use cords in need of repair
•Use no smaller than 6 gauge cords
Grounding
This machine must be grounded! Verify that any exist- ing electrical outlet and circuit you intend to plug into is actually grounded. If it is not, it will be necessary to run a separate copper grounding wire, of the appropri- ate size, from the outlet to a known ground. Under no circumstances should you connect your machine to an ungrounded power source or electrocution or severe shock could occur.
DO NOT attempt to work on your shop electrical system if you are unsure about electrical codes and wiring! Seek assistance from a qualified elec- trician. Ignoring this warning can cause electrocution!
TURN OFF and LOCK your master power switch so no power is available to the sander before
connecting electrical OFF wires! If you ignore this warning seriouselectrical shock may occur causing
injury or death!
Figure 1. Recommended connection type.
ELECTRICAL
Operating Voltage | Amp Draw | Min. Circuit Size | Connection Type | Extension Cord |
220V Operation | 34 Amps | 50A | Hardwire | Not |
|
|
| w/Shutoff Switch | Recommended |