Emerson Figure i manual Single-phase, 1-3 ton model schematic, typical

Page 15

Installation

Figure 9 Single-phase, 1-3 ton model schematic, typical

Conductors Field-Supplied

(See Note 5)

EVAPORATOR UNIT

Unit Alarm

3

Input

 

Connection

 

24V Power

2

Supply

 

From Unit

 

Min 40 Va

 

HGBP Signal

Output4

Connection

1

24V Ground

1-Phase Line

L1

 

Voltage Supply

L2

By Others

 

(See Notes 1 & 3)

 

Earth Ground

By Others

 

 

 

OUTDOOR CONDENSING MODULE

3

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

HP1

 

 

 

 

 

 

W

 

 

 

 

BK

 

 

C1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

4

BR

 

 

 

 

 

 

 

HG1

 

 

 

 

 

 

 

 

 

 

1

See Note 6

 

 

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

HP2

 

 

 

 

 

 

 

 

 

RHTR

 

 

 

 

 

 

 

 

R

BK

 

 

 

 

 

 

 

 

R

BK 1C1

 

 

HG1

 

HGSV

 

 

2C1

 

 

 

 

 

 

 

BK

 

BK

BK

 

 

 

BK

 

LLSV

Supplied on

 

 

 

 

 

 

 

CHTR

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

1-Ton PFC

 

 

 

 

 

 

 

 

 

 

Models Only

 

 

 

 

 

R

 

 

CAP3

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

CAP1

 

 

BDR

 

 

 

R

BK

R R

 

 

 

 

 

 

 

 

PR

 

 

 

 

 

 

 

1

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP2

Y

 

 

R

2

 

 

 

 

 

 

 

R

 

 

 

 

BR

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'FM'

 

C R S

 

 

 

C

CSR

 

 

FAN

 

COMP

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional on

 

 

 

 

Y

 

 

 

 

Selected Units

 

 

 

 

 

NOMENCLATURE

Standard Devices

BDR -- Bleed Resistor

C1 -- Condenser Contactor

CAP1 -- Compressor Capacitor

Run

CAP2 -- Fan Motor Capacitor

CAP3 -- Compressor Capacitor

25,

Start

CHTR -- Compressor Heater

27

COMP -- Compressor

 

 

 

 

FM -- Fan Motor

 

 

HP1 -- High Pressure Switch

 

 

(Auto Reset)

 

 

HP2 -- Pressure Switch Receiver

 

 

(Auto Reset)

 

 

LLSV -- Liquid Line Solenoid Valve

 

 

PR -- Potential Relay

 

 

RHTR -- Receiver Heater

 

 

Optional Devices

 

 

CSR -- Compressor Start Resistor

 

 

HG1 -- Hot Gas Relay

 

 

HGSV -- Hot Gas Solenoid Valve

 

 

WIRE COLOR CODE

 

 

OR - Orange

 

 

R - Red

 

 

BR - Brown

 

 

P - Purple

 

 

GN - Green

 

 

Y - Yellow

 

 

BL - Blue

 

 

BK - Black

 

 

W - White

 

 

Insulation Color

 

 

 

 

GN / Y

 

 

Tracer Color

 

 

 

 

 

1.All units 208/230V, 1 phase. On 208/230V units installed

in Canada only, CSA requires that L1 and L2 are non-neutral supply conductors. L1 et L2 pour conducteurs d'alimentation non-neutres. On other units, L2 is designated neutral. See unit name plate and installation manual for main supply wiring information. Use copper conductors onl y.

2.Use copper conductors only. See unit nameplate for main supply wire sizing data. Wire per local codes.

3.A remote disconnect switch is to be field-supplied and mounted within sight of the condensing unit. See unit nameplate for voltage and amperage requirements.

4.All motors have internal line break overload protectors.

Three-phase motors protected for primary single-phasing conditions.

5.Terminals 1,2,3, and 4 are for connection of control circuit from evaporator unit. Wiring by others to be NEC Class 2 and sized for 1V maximum drop.

6.Wire '1' is connected to the grounded side of the 24V Class 2 circuit.

Factory-Supplied Line Voltage

Field-Installed Line Voltage Wiring

Optional Line Voltage Wiring

Factory-Supplied 24V NEC Class 2 Wiring

Optional 24V Wiring

Factory-Supplied 24V NEC Class 2 Wiring

Factory-Supplied Earth Grounding Wire

Pigtail Leads 24V Wiring

Terminal Strip Connection

Grounding Lug Connection

191642 Rev. 0

11

Image 15
Contents Liebert Prop Fan Condensing Unit = 380/415-3ph-50Hz Example PFH037A-PL7Table of Contents Figures Optional Equipment Prop Fan Condensing UnitsLocation Considerations Equipment InspectionCabinet and floor planning data, horizontal air discharge Dimensional DataNet Weight Model Numbers Dimensional Data, in. mm Lb. kg 60Hz 50HzFootprint Dimensions Wall Mounting Electrical and piping connections, horizontal air discharge Piping and Electrical ConnectionsPFH096A- L 152General piping arrangement Top Air Discharge Models Electrical field connections, 1- to 5-ton unitsElectrical field connections, 8-ton units Single-phase, 1-3 ton model schematic, typical Three-phase, 3-5 ton model schematic, typical Three-phase, 8 ton model schematic, typical Piping for Elevation Differences between PFH and Evaporator Piping ConsiderationsEvaporator Condensing UnitEquivalent lengths for various pipe fittings, ft m Line Size Length Charge R-407C Ft. m Lb-oz kg Pre-Charged Line SetsField-Fabricated Line Sets Refrigerant charge in Liebert pre-charged R-407C line setsRecommended line sizes, OD Cu Liebert PFH unit charge levels and coupling sizeLine Size OD Cu Coupling Size Torque, lb-ft. N-m Installation of Piping to UnitsPiping connection sizes and torque Line charges refrigerant per 100 ft m of Type L copper tubeFilter Drier Selection and Installation Install the New Condensing UnitRemove Existing Condensing Unit General System Charge Requirements Evaporator Charge LevelsEvaporator Charge R-407C Indoor Unit Models Oz kg Low-Voltage Control Wire Connections Low-Voltage Control Wire SizingElectrical Connections Electrical data-High ambient models 105F/41C 60Hz Nominal Input Voltage- Phase Capacity ElectricalNominal Input Voltage-Phase Capacity Electrical Electrical DataElectrical data-High ambient models 105F/41C 50Hz Electrical data-Quiet-Line models 95F/35C 60HzElectrical data Quiet-Line models 95F/35C 50Hz Checklist for Completed InstallationCompressor High Head PressureLiebert Lee-Temp Flood Back Head Pressure Control Adjustment Hot Gas BypassOperation Hot gas bypass diagram Mechanical Failure GeneralCompressor Failure Electrical Failure-BurnoutCompressor Replacement Field Charge Verification Field verification chargeModel Numbers 407C 60 Hz 50 Hz Oz kg Problem Cause Remedy TroubleshootingEtwo Single-Phase&Three-Phase UPS Environmental SystemsWeb Site Monitoring Uni