Campbell Hausfeld NB004100 Cómo Usar la, Mantenimiento, General Safety, Operating The Nailer

Page 3

Manual de Instrucciones

 

Modelo NB004100

Cómo Usar la

 

Para reparar la clavadora

Clavadora (Continuación)

Mantenimiento

Las reparaciones de la clavadora las

debe hacer SOLAMENTE un técnico cali-

 

 

Operating Instructions

 

 

Model NB004100

General Safety

used, manual lubrication through the

4.

Use a pressure regulator on the

air inlet is not required on a daily basis.

 

compressor, with an operating pres-

Information (Continued)

 

The work

 

sure of 0 -125 psi. A pressure regu-

 

 

lator is required to control the

Caution

surface

 

operating pressure of the nailer

indicates

can become damaged by excessive

 

between 70 and 120 psi.

lubrication. Proper lubrication is the

 

 

6 Rote la puerta hacia atrás a la posición cerrada.

7. Extienda el pestillo de alam- bre y colóquelo sobre los gan- chos de la boquilla.

8. Cierre el pestillo empujándolo hacia adentro hasta que ajuste en su posición.

9. Asegúrese que el gatillo y el Elemento de Contacto de

Trabajo se mueven libre-

mente, hacia arriba y hacia abajo sin pegarse o atascarse.

Servicio Técnico

Si desea hacer alguna pregunta refer- ente a la reparación u operación de las clavadoras, sírvase llamar a nuestro número especial, 1-800-543-6400.

Clavos et Repuestos

Use solamente sujetadores Campbell Hausfeld originales calibre 16 (o su equivalente) - (vea la información sobre intercambio de sujetadores). Use sola- mente partes de repuesto Campbell Hausfeld originales. Nunca substituya las partes. No use partes modificadas o partes que no den un rendimiento equivalente al equipo original. El rendimiento de las herramientas, la seguridad y la duración pueden verse reducidos. Cuando ordene partes de repuesto o sujetadores, especifique el número de la parte.

ficado que tenga experiencia.

Para colocarle los sellos

Cada vez que repare una clavadora deberá limpiarle y lubricarle las partes internas. Le recomendamos que use Parker O-lube o un lubricante equiva- lente en todos los anillos en O. A cada anillo en O se le debe dar un baño de lubricante para anillos antes de insta- larlos. Igualmente, deberá ponerle un poco de aceite a todas las piezas que se mueven y muñones. Finalmente, después de haberla ensamblado y antes de probar la herramienta deberá pon- erle unas cuantas gotas de aceite sin detergente 30W u otro aceite similar, en las líneas de aire.

a potentially hazardous situation

owner’s responsibil- ity. Failure to

Sequential Trip Safety

which, if not avoided, MAY result in

lubricate the nailer properly will dra-

Mechanism

minor or moderate injury.

matically shorten the life of the nailer

The tool is equipped with a sequential

Do not make any modifications to the

and void the warranty.

 

 

 

 

trip safety mechanism. When the oper-

tool without first obtaining written

 

 

 

ator depresses the Work Contact

approval from Campbell Hausfeld. Do

1.

Disconnect the

 

Element (WCE) against the work sur-

not use the tool if any shields or

 

air supply from

 

face and then pulls the trigger, a fas-

guards are removed or altered. Do

 

the nailer to

 

tener will be driven.

not use the tool as a hammer.

 

add lubricant.

 

OPERATING A SEQUENTIAL TRIP

Personal injury or tool

 

 

 

damage may occur.

2.

Turn the nailer

 

TOOL

Always check

 

1.

Release trig-

 

so the air inlet

OIL

 

ger and place

that the Work

 

is facing up.

 

 

nose of tool

Contact

 

Place 4-5 drops

 

 

against work

Element (WCE)

 

of 30 W non-

 

 

 

 

 

surface.

is operating

 

detergent oil

 

 

 

 

 

 

properly. A fas-

 

into air inlet.

 

 

 

tener could

 

Do not use

 

2.

Depress the

accidentally be

 

detergent oils,

 

 

Work contact

 

oil additives, or air tool oils. Air tool

 

driven if the WCE is not working

 

 

element (WCE)

 

oils contain solvents which will

 

properly. Personal injury may occur

 

 

against the

 

damage the nailer's internal com-

 

(See "Checking the Work Contact

 

 

work surface

 

ponents.

 

 

Element" Section).

 

 

 

and pull the

3.

After adding

 

 

Disconnect air supply and release

 

 

trigger to drive

 

oil, run nailer

 

 

a fastener.

tension from the pusher before

 

briefly. Wipe

 

3.

Release the

attempting to clear jams because

 

off any excess

 

 

 

 

trigger and lift

tools can be ejected from the front

 

oil from the

 

 

 

 

 

the tool from

of the tool. Personal injury may

 

cap exhaust.

 

 

 

 

 

the work sur-

occur.

 

 

 

 

 

 

 

 

face after

 

 

 

 

 

Notice

 

 

 

 

each fastener

Notas

5 Sp

indicates

RECOMMENDED HOOKUP

 

is driven.

important information, that if not fol-

 

 

Please refer to Airtool Setup

CHECKING THE WORK CONTACT

lowed, MAY cause damage to equipment.

(IN170102AV) for system hookup

ELEMENT (WCE)

 

Avoid using the tool when the mag-

instructions.

 

 

Check the

1.

The air com-

70 psi

azine is empty. Accelerated wear on

the tool may occur.

 

pressor must

Min.

opertion

 

 

be able to

 

of the Work Contact Element (WCE) trip

Clean and check all air supply hoses

 

maintain a

120 psi

mechanism before each use. The WCE

and fittings before connecting the

 

minimum of

Max.

must move freely without binding

tool to an air supply. Replace any

 

70 psi when

 

through its entire travel distance. The

damaged or worn hoses or fittings.

 

the nailer is being used. An inade-

WCE spring must return the WCE to its

Tool performance or durability may

 

quate air supply can cause a loss of

fully extended position after being

be reduced.

 

power and inconsistent driving.

depressed. Do not operate the nailer if

 

the WCE trip mechanism is not operating

 

2. An oiler can be used

 

Air compressors providing air to the

 

properly. Personal injury may occur.

 

to provide oil circula-

 

 

 

 

tool should follow the requirements

 

tion through the

 

1. Disconnect the

established by the American

 

nailer. A filter can

 

air supply from

National Standards Institute

 

be used to remove

 

the nailer.

Standard B19.3-1991; Safety

 

liquid and solid

 

 

Standard for Compressors for

 

impurities which can

 

 

Process Industries. Contact your air

 

rust or “gum up” internal parts of

 

compressor manufacturer for

 

the nailer.

 

 

information.

3.

Use 3/8” air

 

2. Remove all nails from the magazine

 

 

hoses with a

 

Operating The Nailer

 

 

(see Loading/ Unloading The Nailer).

 

minimum

 

 

 

 

 

 

working pres-

 

 

Read this manual and understand all

 

sure of 150

 

3. Make sure the trig-

safety warnings and instructions before

 

psi. Use 1/2” air hoses for 50’ run or

 

ger and work con-

operating the nailer.

 

longer. For better performance,

 

tact element (WCE)

 

 

install a 3/8” quick plug

(1/4” NPT

 

 

move freely up and

LUBRICATION

 

threads) with an inside diameter of

 

down without

This nailer requires lubrication before

 

.315" (8mm) on the nailer and a

 

sticking or binding.

using the nailer for the first time and

 

3/8” quick coupler on the air hose.

 

 

 

 

 

 

before each use. If an inline oiler is

 

 

 

 

 

 

 

 

www.chpower.com

3

Image 3
Contents Description General Safety InformationTable Of Contents Garantía LimitadaInformación de intercambio Nailer Components And SpecificationsModel NB004100 ClavosOperating The Nailer General SafetyCómo Usar la MantenimientoFasteners and Replacement Parts MaintenanceCómo Usar la Clavadora Capacidad DEL Cargador Limited WarrantyComponentes y Especificaciones De la ClavadoraTable Des Matières DescripciónGénéralités sur la Sécurité ÍndicePièces Détachées et Spécifications de la Cloueuse Généralités sur la Sécurité SuiteGarantie Limitée Modèle NB004100Guide De Dépannage Utilisation de la CloueuseAttaches Information D’InterchangeabilitéAttaches et Réparation de la Cloueuse Utilisation de la Cloueuse SuiteEntretien Support Technique