Alignment
3.Lower arm until saw blade just clears the front table. Tighten the yoke lock lever and bevel lock lever.
4.Place a framing square on the table, as shown, with one leg of square firmly against rear edge of front table. Position the blade and square until the leg of the square just contacts a tooth of the blade. Mark this tooth.
5.When the carriage is moved slowly back and forth on the arm, the marked tooth should just touch the square at all points. If marked tooth moves into or away from square the following adjustments are required:
a.Loosen (3) 3/8 - 16 set screws in arm latch at rear of arm as shown.
b.Move the arm in direction to make marked tooth follow edge of square when the saw blade is moved along arm in a “cross cut" manner.
c.Lock miter/arm lock lever.
d.Retighten (3) setscrews in arm latch as tight as possible and recheck "cross cut" travel.
Note: This squaring of the cross cut travel will simul- taneously set both of the 45° miter index positions.
6.Set miter indicator on 0° position as shown.
Miter/Arm Lock Lever
Bevel Index
Lever
Yoke Lock
Lever
Bevel Lock
Marked Lever
Tooth
Loosen Three
Set Screws
3/16" Hex “L” Wrench (Supplied)
Rotate Miter
Indicator To
0° Position
29