Leica 764553, 766558 Beep, Offset, Digital pointfinder image black / white, Level in status field

Page 12

EN

)

We recommend that measurements are initiated using the

 

key when using the device on a tripod in order to prevent loss of sharp-

 

ness.

 

)The settings are reset when the device is switched off.

Beep ( )

You can switch the beep on or off.

Offset ( )

An offset adds or subtracts a specified value automatically to or from all measurements. This function allows tolerances to be taken into account (e.g. unfinished dimensions compared with finished dimensions). If you selected the Offset function in the menu, you can now adjust the value

using the or the key. Pressing the key for longer increases the rate of change of the values. When you reach the desired offset value,

confirm it with the key. The display shows the appropriate symbol

or for as long as the offset value is set.

Digital pointfinder image black / white ( )

The display in pointfinder mode can be changed to black / white.

Level in status field (

)

The Level (in °) in status field can be switched on or off.

Reset - returning the instrument to the factory settings ()

The instrument has a Reset function. If you select the menu function Reset and confirm, the device returns to the factory settings and stack and memory are deleted.

)All customised settings and stored values are also lost.

Calibrate the tilt sensor ( )

You can calibrate the tilt sensor in the device. Calibration requires two measurements on a level surface.

Select calibration mode in the menu .

1 Carry out a first measurement

on a level surface. The device

confirms the measurement with

.

2Rotate the device horizontally through 180° .

3Press the key and confirm that the device was rotated through 180°.

4Press the key and take the second measurement. The device

confirms the measurement with .

The tilt sensor is calibrated.

Menu functions

8

Leica DISTO™ D5 LCA782204a en

Image 12
Contents Leica Disto D5 Page Leica Disto D5 Page Contents Safety InstructionsSymbols used Use of the instrumentPrecautions Limits of useAreas of responsibility Hazards in useElectromagnetic Compatibility EMC Laser classificationFCC statement applic. in U.S Integrated distancemeterStart-up LabellingInserting/replacing batteries Laser Class 2 productsDisplay in normal mode Changing the reference point multifunctional endpieceKeypad See figure EDisplay in digital pointfinder mode SettingsMenu functions Digital pointfinder 4x zoomSetting the unit for tilt measurements Setting the unit for distance measurementsLong range Mode Display illuminationReset returning the instrument to the factory settings BeepOffset Digital pointfinder image black / whiteOperation Measuring Volume FunctionsOverview of the program icons Addition / subtractionTrapezoid measurement Tilt measurementDirect horizontal distance Trapezoid measurement Stake out function Indirect measurementRements and the perimeter Triangle Indirect Measurement determining a distance using Sweep the laser up and down over the ideal target pointMeasurement of the partial lengths As possibleTimer self-triggering AppendixHistorical storage Message codesTechnical data Distance measurementsTilt measurements GeneralWarranty CareMeasuring range Target surfacesPage Exit Leica Disto D5 Switzerland Translation of original text LCA782204a