Leica 766558, 764553, 769459 manual Operation Measuring

Page 13

Operation

 

Measuring

EN

Switching on and off

Switches on the instrument and laser. The display shows the battery symbol until the next button is pressed.

Pressing this button for longer switches the instrument off.

The instrument switches off automatically after six minutes of inactivity.

CLEAR button

The last action is cancelled. While making area or volume measu- rements, each single measurement can be deleted and remeasured in series.

Reference setting

The default reference setting is from the rear of the instrument.

Press this button to take the next measurement from the front edge

. A special beep sounds whenever the reference setting is changed. After a measurement the reference returns automatically to the default setting (rear reference). See figure {H}.

Press this button for longer the front reference is set permanently. Press this button, the rear reference is set again.

Single distance measurement

Press to activate the laser. Press again to trigger the distance measu- rement.

The result is displayed immediately.

Minimum/maximum measurement

This function allows the user to measure the minimum or maximum distance from a fixed measuring point. It can also be used to determine spacings. See figure {I}

This function is commonly used to measure room diagonals (maximum values) or horizontal distances (minimum values).

Press and hold down this button until you hear a beep. Then slowly sweep the laser back and forth and up and down over the desired target point - (e.g. into the corner of a room).

Press to stop continuous measurement. The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line.

Laser continuous ()

Press and hold down the key when switching on the device until the character appears permanently in the display and a beep sounds.Every

further press of the key releases a distance measurement.

Press the key and keep it pressed to switch the device and Laser continuous operation off.

 

 

If the laser is in continuous operation mode, the device

 

 

) switches off automatically after 15 minutes.

Leica DISTO™ D5 LCA782204a en

9

 

Operation

Image 13
Contents Leica Disto D5 Page Leica Disto D5 Page Safety Instructions ContentsSymbols used Use of the instrumentLimits of use PrecautionsAreas of responsibility Hazards in useLaser classification Electromagnetic Compatibility EMCFCC statement applic. in U.S Integrated distancemeterLabelling Start-upInserting/replacing batteries Laser Class 2 productsChanging the reference point multifunctional endpiece Display in normal modeKeypad See figure ESettings Display in digital pointfinder modeMenu functions Digital pointfinder 4x zoomSetting the unit for distance measurements Setting the unit for tilt measurementsLong range Mode Display illuminationBeep Reset returning the instrument to the factory settingsOffset Digital pointfinder image black / whiteOperation Measuring Functions VolumeOverview of the program icons Addition / subtractionTilt measurement Trapezoid measurementDirect horizontal distance Trapezoid measurement Indirect measurement Stake out functionRements and the perimeter Triangle Sweep the laser up and down over the ideal target point Indirect Measurement determining a distance usingMeasurement of the partial lengths As possibleAppendix Timer self-triggeringHistorical storage Message codesDistance measurements Technical dataTilt measurements GeneralCare WarrantyMeasuring range Target surfacesPage Exit Leica Disto D5 Switzerland Translation of original text LCA782204a