GENERAL INFORMATION

You have purchased an air compressor unit consisting of a one cylinder, single-stage air compressor pump and air tank. Included are wheels, regulator, gauges, and handle.

This air compressor requires no oil. Now you can enjoy all the benefits of having an air compressor without ever having to purchase, add or change oil.

Your air compressor can be used for operating paint spray guns, air tools, blow guns, nailers/staplers, air brushes, and inflator kits. An air pressure regulator is required for most of the applications.

An inline air filter which removes moisture and dirt from compressed air should be used where applicable.

An inline regulator can be used if a more precise adjustment of air pressure is needed downstream.

GLOSSARY

CFM: Cubic Feet per Minute.

SCFM: Standard Cubic Feet per Minute; a unit of mea- sure of air delivery.

PSI: Pounds per Square Inch; a unit of measure of pres- sure.

ASME: American Society of Mechanical Engineers; made, tested, inspected and registered to meet the standards of the ASME.

Cut-In Pressure: While the motor is off, air tank pres- sure drops as you continue to use your accessory. When the tank pressure drops to a certain low level and the pressure switch lever is in "Auto", the motor will restart automatically. The low pressure at which the motor auto- matically restarts is called “cut-in pressure.”

Cut-Out Pressure: When you turn on your air compres- sor and it begins to run, air pressure in the air tank be- gins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pres- sure at which the motor shuts off is called “cut-out pres- sure.”

CSA: Electrical products sold in Canada are required to be certified to the applicable CSA standard (s). Canadian Standards Association (CSA) is a standards writing and safety testing organization. Products that are CSA certi- fied have been evaluated and tested and found to meet or exceed the applicable CSA standard (s) for safety and electrical performance.

SPECIFICATION

CHART

Model No.

919.727321

Bore

2 3/8"

Stroke

1.35"

Voltage - Single Phase

120

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Amperage at Maximum Pressure

15.0

Air Tank/Capacity

ASME/25 gal. (U.S.)

Approximate Cut-in Pressure

100

Approximate Cut-out Pressure

130

SCFM @ 40 psi

7.8

SCFM @ 90 psi

5.5

D20015 Rev. 1 6/28/00

6 — ENG

Image 6
Contents Model No Table of Contents Safety Guidelines DefinitionsHazard Important Safety InstructionsWhat can Happen HOW to Prevent IT Risk of Explosion or FireRisk from Flying Objects Risk to BreathingRisk of Electrical Shock Risk of Burns Risk of Property Damage When Transporting CompressorRisk from Moving Parts Risk of FallingGlossary Specification ChartGeneral Information Model No 919.727321Tools Needed for Assembly Description of OperationAssembly BREAK-IN ProceduresOperating Procedures Extension CordsMaintenance Filter RetainerTroubleshooting Guide Problem Cause CorrectionHave compressor checked at Sears Service Center Service and Repair Parts 919.727321 Table DES Matières Mesures DE Sécurité DéfinitionsGarantie Complète DUN AN SUR LES Compresseurs Dair Sears Risque D’EXPLOSION OU D’INCENDIE Mesures DE Sécurité ImportantesAvertissement Risque D’ÉCLATEMENTRisque DE Projection D’OBJETS Prévention Risque PAR Inhalation PréventionRisque DE Choc Électrique Prévention Risque Relié AUX Pièces Mobiles Risque DE BrûluresRisque DE Chute Tableau DES Spécifications Information GénéraleGlossaire De modèle 919.727321Description DU Fonctionnement Outils Nécessaires À L’ASSEMBLAGEAssemblage Procédés DE RodageMise EN Marche RallongesDirectives de rodage Entretien Problème Cause Solution Guide DE DÉ PannageDu compresseur DE Modèle Entretien Pour Commander DES Pièces DE Rechange