12.using the gfci outlet

This charger includes two – GFCI (Ground Fault Circuit Interrupter) outlets located on its back. The purpose of a GFCI outlet is to quickly stop the flow of electricity in the event a ground fault occurs on the device plugged into the battery charger’s GFCI outlet. Ground fault circuit interrupters (GFCI) can help prevent electrical shock or electrocution.

The GFCI outlets provide auxiliary power to 120V devices that require less than 15 amps.

The GFCI must be tested before each use. To test:

12.1Push the “Reset” button located on the GFCI receptacle, first to assure normal GFCI operation.

12.2Plug a night light (with an “ON/OFF” switch) or other product (such as a lamp) into the GFCI receptacle and turn the product “ON.”

12.3Push the “Test” button located on the GFCI receptacle. The night light or other product should go “OFF.”

12.4Push the “Reset” button, again. The light or other product should go “ON” again.

Note: If the light or other product remains “ON” when the “Test” button is pushed, the GFCI is not working properly and should not be used. Call Customer Service at 1-800-SEARS-64 (1-800-732-7764).

12.5The power cord must be plugged into a 3-prong grounded 120V AC wall outlet for the GFCI operation to function. Ground fault circuit interrupters (GFCI) can help prevent electrical shock or electrocution.

12.6If you are charging a battery, the GFCI outlet should be limited to 3 amps of current draw until the charging functions are complete.

12.7The GFCI outlet should not be used while the charger is in the ENGINE START mode.

12.8If using both GFCI outlets at the same time, the amperage cannot exceed 15 amps of both devices combined.

13.operating instructions

SETTING THE CONTROLS

All controls for your charger are located on the front of the unit. Follow these instructions to obtain the accurate charge level for your battery.

13.1POWER ON/OFF SWITCH

Make sure your charger is OFF when connecting or disconnecting your charger from the vehicle and power source. Turn your charger ON only when it is connected to the vehicle and plugged into a 3-prong grounded wall outlet.

13.2BATTERY VOLTAGE SELECT

When charging, testing or starting 12 volt systems, select 12 VOLT. Select

11

Image 13 Contents
OPERATOR’S Manual Table of Contents Important Safety Instructions Preparing to Charge Personal PrecautionsFollow These Steps When Battery is Installed in ve- hicle DC Connection PrecautionsCharger Location Page Page Grounding Methods Parts Replacement Parts List DieHard Description Part NumberParts Tools Needed Charger features Assembly instructionsTo attach the axle assembly Page Setting the Controls Using the gfci outletPower ON/OFF Switch Battery Voltage SelectRate SettingsMaximum Time IncrementCharge Rate in amps Charger is in Manual modeVoltage Timer mode Battery is charged Automatic modeThere is a problem with the battery or connections Engine StartAmp Hours = Reserve Capacity + Charge Rate Battery SIZE/RATING Charging Time Hours AMPSpecific Gravity Percent of Charge Needed Charger Setting Hours Charger SettingUsing the engine start feature ExampleStorage instructions Maintenance instructionsProblem Possible Cause SOLUTION/REASONS TroubleshootingTHREE-YEAR Full Warranty WarrantyPage