Sears 28.71234 operating instructions Grounding Methods

Page 8

8.3Recommended minimum AWG size for extension cords for battery chargers:

AC input rating,

 

 

AWG size of cord

 

 

amperesa

 

Length of cord, feet (m)

 

 

At least

But less

25

50

100

 

150

 

than

(7.6)

(15.2)

(30.5)

 

(45.6)

 

 

 

 

0

2

18

 

18

18

 

16

 

2

3

18

 

18

16

 

14

 

3

4

18

 

18

16

 

14

 

4

5

18

 

18

14

 

12

 

5

6

18

 

16

14

 

12

 

6

8

18

 

16

12

 

10

 

8

10

18

 

14

12

 

10

 

10

12

16

 

14

10

 

8

 

12

14

16

 

12

10

 

8

 

14

16

16

 

12

10

 

8

 

16

18

14

 

12

8

 

8

 

18

20

14

 

12

8

 

6

 

aIf the input rating of a charger is given in watts rather than in amperes, the corresponding ampere rating is to be determined by dividing the wattage rating by the voltage rating ‒ for example:

1250 watts/125 volts = 10 amperes

8.4

Grounding Methods

6

Image 8 Contents
OPERATOR’S Manual Table of Contents Important Safety Instructions Personal Precautions Preparing to ChargeCharger Location DC Connection PrecautionsFollow These Steps When Battery is Installed in ve- hicle Page Page Grounding Methods Replacement Parts List DieHard Description Part Number PartsCharger features Assembly instructions Parts Tools NeededTo attach the axle assembly Page Using the gfci outlet Setting the ControlsPower ON/OFF Switch Battery Voltage SelectSettings RateMaximum Time IncrementVoltage Charger is in Manual modeCharge Rate in amps Battery is charged Automatic mode Timer modeThere is a problem with the battery or connections Engine StartSpecific Gravity Percent of Charge Needed Charge Rate Battery SIZE/RATING Charging Time Hours AMPAmp Hours = Reserve Capacity + Charger Setting Charger Setting HoursUsing the engine start feature ExampleMaintenance instructions Storage instructionsTroubleshooting Problem Possible Cause SOLUTION/REASONSWarranty THREE-YEAR Full WarrantyPage
Related manuals
Manual 24 pages 43.7 Kb