Emerson 2330MKII manual Troubleshooting Indication

Page 36

BOOK 0958-B

TABLE 6. TROUBLESHOOTING

INDICATION

POSSIBLE CAUSE

9. Line and motor arma

Motor overloaded

ture current excessive

 

 

Open shunt field winding or wiring to

 

the motor shunt field

10. Shunt field current a

 

Shunt field connected for incorrect

too low

voltage

 

 

 

 

Diode D39, D40, D41, or D42 failure

 

 

 

Shunt field connected for incorrect

11. Shunt field current a

voltage

 

 

too high

Shunt field windings shorted

 

 

 

 

Ventilation insufficient

 

 

 

Excessive motor load at low speed

 

 

12. Motor thermal guard

Line and motor armature current

tripped (if used)

excessive

 

 

 

Motor overheating from friction

 

 

 

Shorted motor windings or faulty bear-

 

ings

CORRECTIVE ACTION

Check shunt field current.a Low shunt field current causes excessive armature current. If field current is adequate, check for a mechani cal overload. If the unloaded motor shaft does not rotate freely, check motor bearings. Also check for a shorted motor armature. Motor overload can also be caused by incorrect gear ratio. Correct accordingly.

Check the motor shunt field and associated circuitry for a loose connection or a broken wire. Repair accordingly.

Check motor rating and refer to Table 12 on page 34.

Replace faulty diode or the control board.

Check motor rating and refer to Table 12 on page 34.

Measure the shunt field resistance and com pare with the motor rating. Repair or replace the motor.

Remove dirt, dust, and debris from the motor intake and exhaust screens.

Reduce the load or increase the speed.

See Indication 9.

Check for misalignment. Realign the motor.

Repair or replace the motor.

a. Does not apply to permanent-magnet motors. b. Does not apply to shunt-wound motors.

28

Image 36
Contents Book 0958-B Page 3 HP Book 0958-B Table of Contents List of Tables List of IllustrationsBlank Following must be strictly adhered to at all times Section General Information Introduction General DescriptionModel Types Motor Selection Section Installation Installation GuidelinesDo not use solid wire Installing the Controller Jumper J4 Position Motor Armature Current Rating AmperesInstall the controller cover, if used Controller Mounting Configurations Controller Mounting Dimensions Logic connection diagram, Run-Stop-Jog Switch Book 0958-B Book 0958-B Book 0958-B Signal Connection Diagram, Motor Speed Potentiometer Signal Connection Diagram, Tachometer Feedback Signal Connection Diagram, 4-20mA Interface Page Initial Potentiometer Settings Description Initial StartupBook 0958-B Section Operation Power ON/OFF RUNStop Speed Control Torque ControlJOG Reverse Load MonitorCurrent Loop Transducers Inoperative MotorBlank Section Maintenance and Repair General Adjustment Instructions AccelerationDeceleration IR CompensationTachometer Feedback Setup Minimum SpeedCurrent Limit Troubleshooting Indication Possible Cause Corrective ActionOne or more SCR‘s or Diode D1b Troubleshooting Indication Possible Cause Corrective ActionTroubleshooting Indication Section Parts List Parts LIST, Series 2330 Mkii Controllers Fincor PartPart Blank Section Ratings and Specifications 120%Operating Voltages and Signals Controller WeightsPerformance Characteristics Operating ConditionsAdjustments SpecificationsShunt Field Data Tachometer Feedback Voltage Selection Section Drawings Functional Schematic, Series 2330MKII Series 2330MKII Control Board, 1/6 3HP Blank Index Maximum Speed Book 0958-B