Hobart 3225DX manual Installing Ether Cylinder Optional Ether Starting Aid

Page 21

4-6. Installing Ether Cylinder (Optional Ether Starting Aid)

1

2

3 4

5

6

YStop engine.

YImproper handling or expo- sure to ether can harm your health. Follow manufactur- er’s safety instructions on cylinder.

YDo not use Ether Starting Aid while engine is running.

Open side door(s).

1Ether Cylinder

2Nozzle

Remove cover and clean cylinder nozzle.

3Clamp

4Fitting

5Cap

6Valve

Remove cap and clean fitting. Install cylinder on fitting. Tighten clamp.

.After installing cylinder, wait at least 10 minutes before using to let ether particles settle and prevent atomizer plugging.

Put cap on fitting when cylinder is removed.

ether1 12/96 – ST-153 382-A / Ref. ST-188 449

4-7. Connecting To Weld Output Terminals

3

2

Open left side door.

1 Bracket

Route cables through bracket.

2Positive (+) Weld Output Terminal

3Negative (–) Weld Output Ter- minal

For Stick welding Direct Current Electrode Positive (DCEP), con- nect work cable to (–) terminal and electrode holder cable to (+) terminal.

For Direct Current Electrode Nega- tive (DCEN), reverse cable connections.

If equipped with optional polarity switch, connect electrode holder cable to Electrode (–) terminal and work cable to Work (+) terminal.

For FCAW welding, connect work cable to (–) terminal and wire feeder cable to (+) terminal.

1

Close door.

Tools Needed:

3/4 in

Ref. ST-800 162-A

OM-130 098 Page 17

Image 21
Contents Processes OM-130Visit our website at AugustFrom Hobart to You Table of Contents Page Arc Welding Hazards Symbol UsageElectric Shock can kill ARC Rays can burn eyes and skinEngine Hazards Moving Parts can cause injury Battery Explosion can BlindEngine Exhaust Gases can kill Engine Heat can cause fireEMF Information Principal Safety StandardsRadiation can cause interference ARC Welding can cause interferenceConsignes DE SÉ Curité Lire Avant Utilisation Signification des symbolesUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un in- cendie ou une explosionDES PIÈ CES Chaudes peuvent provoquer des brû lures graves LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut DES Organes Mobiles peuvent provoquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie LA Chute DE L’APPAREIL peut blesserInformation sur les champs é lectromagné tiques Principales normes de sé curitéLE Soudage À L’ARC risque de provoquer des interfé rences Consignes relatives aux stimulateurs cardiaquesDefinitions Symbols And DefinitionsSpecifications Weld, Power, And Engine SpecificationsDimensions, Weights, And Operating Angles Fuel Consumption Warranty Minutes Welding Minutes RestingDuty Cycle And Overheating 40% Duty Cycle At 400 AmperesVolt-Ampere Curves AC Auxiliary PowerOptional AC Power Plant Curves Installation Installing Welding GeneratorInstalling Muffler Pipe Do not overfill battery cells Activating The Dry Charge BatteryVent Caps For 12 MinutesEngine Prestart Checks Connecting The BatteryConnect Negative Cable Last FullInstalling Ether Cylinder Optional Ether Starting Aid Connecting To Weld Output TerminalsPut cap on fitting when cylinder is removed Selecting Weld Cable Sizes 100 ft 30 m Or Less10 100% Duty Cycle OM-130 098 Controls See Section Operating the Welding GeneratorRemote A/V Control Description Of Front Panel Controls See SectionVolt And 240 Volt Duplex Receptacles Operating Auxiliary EquipmentOptional Auxiliary Power Receptacles Gfci Receptacle OptionAustralian, British, And South African Receptacle Options Connecting Optional Auxiliary Power Plant Maintenance and Troubleshooting Maintenance Label To clean air filter Servicing Air CleanerStop engine HoseServicing Fuel And Lubrication Systems To change oil and filterTo replace primary fuel filter Adjusting Engine Speed Standard ModelsModels With Automatic Idle Optional Full Empty Overload Protection Servicing Optional Ether Starting AidInspecting And Cleaning Optional Spark Arrestor TroubleshootingWelding Check connections to auxiliary power plant see Section Auxiliary PowerEngine Maximum see SectionCircuit Diagram For Welding Generator Electrical DiagramWetstacking RUN-IN ProcedureStop engine Do not touch hot exhaust Run-In Procedure Using Load BankBank/grid From flammablesRun-In Procedure Using Resistance Grid Auxiliary Power Guidelines Selecting EquipmentGrounding Generator To Truck Or Trailer Frame How Much Power Does Equipment Require? Grounding When Supplying Building SystemsEarth ground if supplying Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP xObtain and install correct switch Power Company ServiceSafety practices 120 Single-PhaseCurrent Load Watts Amperes Selecting Extension Cord Use Shortest Cord Possible118 117 116 115 Parts List71Includes 113 114 11065 FIG Dia Part Description Quantity Mkgs 126 102 Optional Equipment Panel, Front w/Components Panel, Front w/Components -1 Item 11 10 GeneratorGenerator -1 Item Includes 114Support ServiceContact your Distributor for Hobart Welding ProductsCall

3225DX specifications

The Hobart 3225DX is a robust and versatile commercial dishwasher designed to meet the needs of restaurants, catering services, and institutions requiring efficient dishwashing solutions. Engineered for high performance, this machine combines advanced technology with user-friendly features to deliver exceptional cleaning results.

One of the standout features of the Hobart 3225DX is its high capacity. It can wash up to 60 racks per hour, making it suitable for busy kitchens. The machine is designed to handle a wide variety of dishware, glassware, and utensils, ensuring a thorough clean for all types of kitchenware.

Equipped with a powerful two-speed wash pump, the Hobart 3225DX guarantees optimal cleaning efficiency. Users can choose between a standard wash cycle for regular soiled items and a more intense cycle for heavily soiled dishware. This flexibility allows kitchen staff to adjust the machine's performance based on their specific needs.

The dishwasher features an advanced filtration system that minimizes the need for frequent cleaning of the internal components. This system captures food particles and debris, enhancing the machine's longevity and maintaining consistently clean results. Additionally, the Hobart 3225DX is designed with a built-in booster heater that increases water temperature to ensure optimal sanitization, complying with health and safety standards.

User convenience is a key consideration in the design of the Hobart 3225DX. The intuitive controls and clear display make operation straightforward, even for first-time users. The machine is also engineered for easy maintenance, with accessible components that allow for quick service and troubleshooting.

Another notable characteristic is its energy efficiency. The Hobart 3225DX is designed to minimize water and energy consumption without compromising performance. This aligns with the growing emphasis on sustainability in the foodservice industry, offering an eco-friendly solution that helps businesses reduce operational costs.

In summary, the Hobart 3225DX is an efficient, high-capacity commercial dishwasher that combines powerful cleaning capabilities with user-friendly features. Its advanced wash pump, effective filtration system, and energy-efficient design make it an ideal choice for any busy kitchen looking to streamline dishwashing operations and maintain the highest hygiene standards.